Open-path methane sensing via backscattered light in a nonlinear interferometer

Nonlinear interferometry has widespread applications in sensing, spectroscopy, and imaging. However, most implementations require highly reflective mirrors and precise optical alignment, drastically reducing their versatility and usability in outdoor applications. This work is based on stimulated parametric downconversion, demonstrating methane absorption spectroscopy in the mid-infrared (MIR) region by detecting near-infrared photons using a silicon-based CMOS camera. The MIR light, used to probe methane, is diffusely backscattered from a Lambertian surface, experiencing significant transmission loss. We implement a single-mode confocal illumination and collection scheme, using a two-lens system to mode-match the interfering beams to achieve background methane detection at a distance of 4.6 m under a 57 dB loss. Our method is also extended to real-world surfaces, such as glass, brushed metal, and a leaf, showing robust background methane sensing with various target materials.

Authors

Institutions

Publication Details

Journal
APL Photonics
Published
2025-11-01
DOI
https://doi.org/10.1063/5.0289408
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Open-path methane sensing via backscattered light in a nonlinear interferometer

Alex S. Clark, Weijie Nie, John Rarity, Jingrui Zhang et al.
APL Photonics
Spectroscopy and Laser Applications
article

Open-path methane sensing via backscattered light in a nonlinear interferometer

Alex S. Clark, Weijie Nie, John Rarity, Jingrui Zhang, Haichen Zhou, Jinghan Dong, Arthur C. Cardoso
article en

Abstract

Nonlinear interferometry has widespread applications in sensing, spectroscopy, and imaging. However, most implementations require highly reflective mirrors and precise optical alignment, drastically reducing their versatility and usability in outdoor applications. This work is based on stimulated parametric downconversion, demonstrating methane absorption spectroscopy in the mid-infrared (MIR) region by detecting near-infrared photons using a silicon-based CMOS camera. The MIR light, used to probe methane, is diffusely backscattered from a Lambertian surface, experiencing significant transmission loss. We implement a single-mode confocal illumination and collection scheme, using a two-lens system to mode-match the interfering beams to achieve background methane detection at a distance of 4.6 m under a 57 dB loss. Our method is also extended to real-world surfaces, such as glass, brushed metal, and a leaf, showing robust background methane sensing with various target materials.

APL PhotonicsVol. 10(11)
University of Bristol (GB), Bristol Robotics Laboratory (GB)
QuantIC, Royal Society, University of Bristol, China Scholarship Council, Engineering and Physical Sciences Research Council
Openalex Percentile: Top 68%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.