The Implications of Non-Constant Hygrothermal Parameters on Heat and Moisture Transfer in Rammed Earth Walls Across Diverse Climate Zones

As an eco-friendly natural building material, rammed earth possesses outstanding hygrothermal performance, which plays a vital role in achieving the goals of sustainable architecture. However, most existing simulations assume constant hygrothermal parameters, resulting in considerable discrepancies between predicted and actual energy performance and consequently underestimating the true passive regulatory potential of rammed earth. To enhance the accuracy of energy consumption predictions in rammed earth buildings, this study integrates experimental measurements with dynamic simulations and experimentally determines both the constant and non-constant hygrothermal parameters of rammed earth. By integrating experimental and simulation approaches, this study reveals a strong positive linear correlation between the thermal conductivity of rammed earth and its moisture content (R2 = 0.9919), increasing from 0.77 W/(m·K) to 1.38 W/(m·K) as moisture content rises from 0% to 14%, whereas the moisture resistance factor decreases exponentially with increasing relative humidity (RH). Subsequently, the two sets of hygrothermal parameters were implemented in the WUFI-Plus simulation platform to conduct annual dynamic simulations across five representative Chinese climate zones (Harbin, Beijing, Nanjing, Guangzhou, and Dali), systematically comparing the performance differences between the “non-constant” and “constant” parameter models. The results show that the non-constant parameter model effectively captures the dynamic hygrothermal regulation of rammed earth, exhibiting superior passive performance. It predicts substantially lower building energy loads, with heating energy reductions most pronounced in Harbin and Beijing (16.9% and 15.5%) and cooling energy reductions most significant in Guangzhou and Nanjing (15.8% and 15.2%). This study confirms that accurately accounting for the dynamic hygrothermal coupling process is fundamental to reliably evaluating the performance of hygroscopic materials such as rammed earth, providing a robust scientific basis for promoting energy-efficient, low-carbon, and climate-responsive sustainable building design.

Authors

Institutions

Publication Details

Journal
Sustainability
Published
2025-11-16
DOI
https://doi.org/10.3390/su172210238
Primary Topic
Hygrothermal properties of building materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Implications of Non-Constant Hygrothermal Parameters on Heat and Moisture Transfer in Rammed Earth Walls Across Diverse Climate Zones

Xiawen Ma, Shimeng Hao, Jun Mu
Sustainability
Hygrothermal properties of building materials
article

The Implications of Non-Constant Hygrothermal Parameters on Heat and Moisture Transfer in Rammed Earth Walls Across Diverse Climate Zones

Xiawen Ma, Shimeng Hao, Jun Mu
article en

Abstract

As an eco-friendly natural building material, rammed earth possesses outstanding hygrothermal performance, which plays a vital role in achieving the goals of sustainable architecture. However, most existing simulations assume constant hygrothermal parameters, resulting in considerable discrepancies between predicted and actual energy performance and consequently underestimating the true passive regulatory potential of rammed earth. To enhance the accuracy of energy consumption predictions in rammed earth buildings, this study integrates experimental measurements with dynamic simulations and experimentally determines both the constant and non-constant hygrothermal parameters of rammed earth. By integrating experimental and simulation approaches, this study reveals a strong positive linear correlation between the thermal conductivity of rammed earth and its moisture content (R2 = 0.9919), increasing from 0.77 W/(m·K) to 1.38 W/(m·K) as moisture content rises from 0% to 14%, whereas the moisture resistance factor decreases exponentially with increasing relative humidity (RH). Subsequently, the two sets of hygrothermal parameters were implemented in the WUFI-Plus simulation platform to conduct annual dynamic simulations across five representative Chinese climate zones (Harbin, Beijing, Nanjing, Guangzhou, and Dali), systematically comparing the performance differences between the “non-constant” and “constant” parameter models. The results show that the non-constant parameter model effectively captures the dynamic hygrothermal regulation of rammed earth, exhibiting superior passive performance. It predicts substantially lower building energy loads, with heating energy reductions most pronounced in Harbin and Beijing (16.9% and 15.5%) and cooling energy reductions most significant in Guangzhou and Nanjing (15.8% and 15.2%). This study confirms that accurately accounting for the dynamic hygrothermal coupling process is fundamental to reliably evaluating the performance of hygroscopic materials such as rammed earth, providing a robust scientific basis for promoting energy-efficient, low-carbon, and climate-responsive sustainable building design.

SustainabilityVol. 17(22)
Beijing University of Civil Engineering and Architecture (CN)
Openalex Percentile: Top 63%
Hygrothermal properties of building materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.