Ex-vivo biomechanical characterization of porcine cava vein

In recent years, percutaneous procedures are gradually replacing open heart surgery for the treatment of tricuspid valve pathological conditions deploying prosthetic devices (i.e., stent-graft) within the proximal portion of the cava veins. Nevertheless, since there is no comprehensive mechanical characterization of the venous district, the devices exploited in these procedures are very similar to the ones exploited in aortic treatment, involving possible critical periprocedural complications. According to the international standards adopted for the design of novel vascular devices, this study presents an experimental set-up to investigate the biomechanics of fifteen porcine cava veins with the development of a semi-automatic protocol for compliance testing. During the tests, 2D echo images of the vessel lumen are acquired for different steps within a pressure range of 5-20 mmHg. The acquired pressure-diameter curves of the samples are then derived by a polynomial function, furthermore, the compliance values are obtained using the corresponding equations as well. The results demonstrate that the cava vein exhibits a hyperelastic behavior, with a nonlinear relationship between pressure and diameter. At low pressures, the veins demonstrate high compliance and reduced stiffness (11.54 ± 4.76 kPa). On the contrary, when pressures exceed the normal physiological range (i.e., greater than 10 mmHg), the veins become stiffer (294.70 ± 233.00 kPa). The developed set-up, based on an ex-vivo porcine model, proved to be a robust tool for the assessment of vein biomechanics and for preclinical benchmarking of novel venous endovascular devices.

Authors

Institutions

Publication Details

Journal
Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials
Published
2025-11-17
DOI
https://doi.org/10.1016/j.jmbbm.2025.107271
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ex-vivo biomechanical characterization of porcine cava vein

Ariel Pascaner, Martina Schembri, Michele Conti, Alessandro Caimi et al.
Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials
Coronary Interventions and Diagnostics
article

Ex-vivo biomechanical characterization of porcine cava vein

Ariel Pascaner, Martina Schembri, Michele Conti, Alessandro Caimi, Ferdinando Auricchio, Eleonora Luzietti
article en

Abstract

In recent years, percutaneous procedures are gradually replacing open heart surgery for the treatment of tricuspid valve pathological conditions deploying prosthetic devices (i.e., stent-graft) within the proximal portion of the cava veins. Nevertheless, since there is no comprehensive mechanical characterization of the venous district, the devices exploited in these procedures are very similar to the ones exploited in aortic treatment, involving possible critical periprocedural complications. According to the international standards adopted for the design of novel vascular devices, this study presents an experimental set-up to investigate the biomechanics of fifteen porcine cava veins with the development of a semi-automatic protocol for compliance testing. During the tests, 2D echo images of the vessel lumen are acquired for different steps within a pressure range of 5-20 mmHg. The acquired pressure-diameter curves of the samples are then derived by a polynomial function, furthermore, the compliance values are obtained using the corresponding equations as well. The results demonstrate that the cava vein exhibits a hyperelastic behavior, with a nonlinear relationship between pressure and diameter. At low pressures, the veins demonstrate high compliance and reduced stiffness (11.54 ± 4.76 kPa). On the contrary, when pressures exceed the normal physiological range (i.e., greater than 10 mmHg), the veins become stiffer (294.70 ± 233.00 kPa). The developed set-up, based on an ex-vivo porcine model, proved to be a robust tool for the assessment of vein biomechanics and for preclinical benchmarking of novel venous endovascular devices.

Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materialsVol. 174
University of Pavia (IT), IRCCS Policlinico San Donato (IT)
Openalex Percentile: Top 47%
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.