Evaluating the impact of ventilation configurations after fire suppression on temperature, visibility, and carbon monoxide levels at different heights in a firefighter training environment with training fuels
This study analyzes post-suppression ventilation strategies in a simulated 70 m 2 residential unit within a firefighter training environment, utilizing training fuels. It compares five tactical approaches: ventilation-controlled, ventilation by using thermal buoyancy, positive pressure ventilation (PPV), and hydraulic ventilation with single and dual openings. Results demonstrate that tactical ventilation significantly outperformed ventilation-controlled strategies. While positive pressure ventilation achieved superior temperature reduction (25.49% at 1.7 m height), it caused temporary CO increases and visibility loss due to turbulence. Hydraulic ventilation with dual openings proved most effective overall, delivering the highest visibility category and 44.71% CO reduction while maintaining clear smoke extraction. These findings offer evidence-based guidance for fire services to refine their post-suppression protocols, ultimately enhancing firefighter safety and improving survival outcomes in residential fires.
Authors
- Cyh Leung
- Tam Wai Kit
- Au Pak Yin Garry (ORCID: https://orcid.org/0009-0003-4581-1237)
Institutions
- New York City Fire Department (US)
Publication Details
- Journal
- Journal of Fire Sciences
- Published
- 2025-11-17
- DOI
- https://doi.org/10.1177/07349041251390888
- Primary Topic
- Fire dynamics and safety research
- Type
- article
- Field-Weighted Citation Impact
- 0.00