FEATURES OF ASSESSING THE FIRE RESISTANCE LIMIT OF LOAD-BEARING STRUCTURES

The theoretical and practical aspects of assessing the fire resistance limit of load-bearing building structures occupy a very important place in the system of building fire safety analysis. The fire resistance limit is a key parameter that determines the ability of structures to maintain strength and stability under high-temperature fire conditions. Modern approaches, including experimental and computational methods, as well as numerical modeling methods used in engineering practice, are considered. A comparative analysis of Russian and international regulatory documents regulating fire resistance assessment methods is presented. The factors influencing the accuracy and reliability of the assessment are considered: properties of materials, features of temperature exposure, geometric parameters of structures, types of loads. Special attention is paid to the use of software systems to simulate the thermal and mechanical behavior of structures in a fire. The necessity of an integrated approach to the assessment of fire resistance, combining computational and experimental methods, is substantiated. The findings can be used in the design of public buildings and the development of measures to ensure their fire safety.

Authors

Institutions

Publication Details

Journal
MONITORING AND EXPERTISE IN SAFETY SYSTEM
Published
2025-10-21
DOI
https://doi.org/10.61260/2304-0130-2025-3-19-26
Primary Topic
Fire effects on concrete materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

FEATURES OF ASSESSING THE FIRE RESISTANCE LIMIT OF LOAD-BEARING STRUCTURES

Alexandra Guzhva, Ekaterina Sidorova
MONITORING AND EXPERTISE IN SAFETY SYSTEM
Fire effects on concrete materials
article

FEATURES OF ASSESSING THE FIRE RESISTANCE LIMIT OF LOAD-BEARING STRUCTURES

Alexandra Guzhva, Ekaterina Sidorova
article en

Abstract

The theoretical and practical aspects of assessing the fire resistance limit of load-bearing building structures occupy a very important place in the system of building fire safety analysis. The fire resistance limit is a key parameter that determines the ability of structures to maintain strength and stability under high-temperature fire conditions. Modern approaches, including experimental and computational methods, as well as numerical modeling methods used in engineering practice, are considered. A comparative analysis of Russian and international regulatory documents regulating fire resistance assessment methods is presented. The factors influencing the accuracy and reliability of the assessment are considered: properties of materials, features of temperature exposure, geometric parameters of structures, types of loads. Special attention is paid to the use of software systems to simulate the thermal and mechanical behavior of structures in a fire. The necessity of an integrated approach to the assessment of fire resistance, combining computational and experimental methods, is substantiated. The findings can be used in the design of public buildings and the development of measures to ensure their fire safety.

MONITORING AND EXPERTISE IN SAFETY SYSTEMVol. 2025(3)
Academy of the State Fire Service EMERCOM of Russia (RU)
Openalex Percentile: Top 64%
Fire effects on concrete materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

FEATURES OF ASSESSING THE FIRE RESISTANCE LIMIT OF LOAD-BEARING STRUCTURES — Alexandra Guzhva, Ekaterina Sidorova · MONITORING AND EXPERTISE IN SAFETY SYSTEM (2025) | TGRS Research Map | TGRS