A novel method for fabricating deformable aortic dissection models and its application in interventional treatment assessment

Interventional procedure design and in vitro experimental studies for aortic dissection (AD) currently lack mature and effective modeling methods. In this study, a model of the true lumen and false lumen was reconstructed based on a patient with type B aortic dissection. 3D printing was utilized to model the true and false lumens of the aorta. A highly transparent aortic dissection model was produced using a newly developed four-step casting-spin-coating approach. The model was subsequently employed for in vitro stent deployment procedures in both the interventional operating room and laboratory. Under monitoring by a DSA system, the stent graft was successfully delivered via the femoral artery and deployed at the target site for covering the proximal tear. The silicone AD model, before and after stent treatment, was connected to an in-house pulsatile circuit to investigate the variations in pressure waveforms in both the true and false lumens. Experimental results showed that during the systolic phase, fluid flowed from the true lumen into the false lumen at both the proximal and distal ends, while during the diastolic phase, fluid flowed out of the false lumen. After stent treatment, the systolic index, defined as the ratio of the systolic pressure in the true lumen (TL) to that in the false lumen (FL), increased by 4.64% and 3.62% respectively at the proximal and distal ends, suggesting a favorable outcome for the AD treatment. This dissection model is believed to have significant clinical and scientific value in interventional surgery planning and in vitro visualization experiments.

Authors

Institutions

Publication Details

Journal
Proceedings of the Institution of Mechanical Engineers Part C Journal of Mechanical Engineering Science
Published
2025-11-16
DOI
https://doi.org/10.1177/09544062251389464
Primary Topic
Aortic Disease and Treatment Approaches
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel method for fabricating deformable aortic dissection models and its application in interventional treatment assessment

Ying He, Dengji Liu, Qingzhuo Chi, Kai Yin et al.
Proceedings of the Institution of Mechanical Engineers Part C Journal of Mechanical Engineering Science
Aortic Disease and Treatment Approaches
article

A novel method for fabricating deformable aortic dissection models and its application in interventional treatment assessment

Ying He, Dengji Liu, Qingzhuo Chi, Kai Yin, Yong Luan, Zhong Gao
article en

Abstract

Interventional procedure design and in vitro experimental studies for aortic dissection (AD) currently lack mature and effective modeling methods. In this study, a model of the true lumen and false lumen was reconstructed based on a patient with type B aortic dissection. 3D printing was utilized to model the true and false lumens of the aorta. A highly transparent aortic dissection model was produced using a newly developed four-step casting-spin-coating approach. The model was subsequently employed for in vitro stent deployment procedures in both the interventional operating room and laboratory. Under monitoring by a DSA system, the stent graft was successfully delivered via the femoral artery and deployed at the target site for covering the proximal tear. The silicone AD model, before and after stent treatment, was connected to an in-house pulsatile circuit to investigate the variations in pressure waveforms in both the true and false lumens. Experimental results showed that during the systolic phase, fluid flowed from the true lumen into the false lumen at both the proximal and distal ends, while during the diastolic phase, fluid flowed out of the false lumen. After stent treatment, the systolic index, defined as the ratio of the systolic pressure in the true lumen (TL) to that in the false lumen (FL), increased by 4.64% and 3.62% respectively at the proximal and distal ends, suggesting a favorable outcome for the AD treatment. This dissection model is believed to have significant clinical and scientific value in interventional surgery planning and in vitro visualization experiments.

Proceedings of the Institution of Mechanical Engineers Part C Journal of Mechanical Engineering ScienceVol. 240(3)
Liaoning University (CN), Dalian Medical University (CN), Dalian University of Technology (CN), Dalian Municipal Central Hospital (CN), First Affiliated Hospital of Dalian Medical University (CN), China Medical University (CN)
Openalex Percentile: Top 50%
Aortic Disease and Treatment Approaches
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.