Combined cooling for CSP plants: Modeling, experimental validation and optimization analysis

The global development of Concentrated Solar Thermal Power (CSP) projects demands new technologies that enhance the thermal efficiency of power cycles without increasing costs or environmental impact. Among the subsystems of the power cycle, the cooling circuit plays a critical role, as it must minimize water consumption while maintaining high efficiency; a challenge that is particularly relevant in arid regions where many CSP plants are installed. This paper presents a model for a cooling system that combines Dry Cooling (DC) and Wet Cooling Tower (WCT) technologies, enabling multiple operating configurations (parallel, series, parallel–series, only-WCT, and only-DC). The model was validated using experimental data from a 200 kW th pilot plant, achieving a Mean Absolute Error (MAE) below 0.97 ° C for system temperatures and 19.4 l/h for water consumption. An optimization analysis was also performed, demonstrating the potential of the proposed technology to provide adaptive cooling for CSP plants under varying seasonal and operating conditions. For the pilot plant during summer, optimally combining DC and WCT in a parallel series configuration enabled a nearly continuous variation in specific electricity consumption, ranging from 0.06 kW e / kW th in only-DC operation to values up to 90 % lower in only-WCT mode, at a water usage cost of 1.48 l/kWh th . • Physical model to predict the performance of combined cooling systems. • Validated the model experimentally, achieving a MAE of 0.41 ° C for the condensate temperature. • Performed optimal operation analysis across multiple case studies. • Demonstrated the potential of combined cooling for CSP plants using optimization tools.

Authors

Institutions

Publication Details

Journal
Energy Conversion and Management
Published
2025-11-17
DOI
https://doi.org/10.1016/j.enconman.2025.120752
Primary Topic
Adsorption and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Combined cooling for CSP plants: Modeling, experimental validation and optimization analysis

J. Muñoz-Cámara, Lídia Roca, Bartolomé Ortega-Delgado, Juan Miguel Serrano Rodríguez et al.
Energy Conversion and Management
Adsorption and Cooling Systems
article

Combined cooling for CSP plants: Modeling, experimental validation and optimization analysis

J. Muñoz-Cámara, Lídia Roca, Bartolomé Ortega-Delgado, Juan Miguel Serrano Rodríguez, P. Navarro, Patricia Palenzuela, Javier Ruiz Ramírez
article en

Abstract

The global development of Concentrated Solar Thermal Power (CSP) projects demands new technologies that enhance the thermal efficiency of power cycles without increasing costs or environmental impact. Among the subsystems of the power cycle, the cooling circuit plays a critical role, as it must minimize water consumption while maintaining high efficiency; a challenge that is particularly relevant in arid regions where many CSP plants are installed. This paper presents a model for a cooling system that combines Dry Cooling (DC) and Wet Cooling Tower (WCT) technologies, enabling multiple operating configurations (parallel, series, parallel–series, only-WCT, and only-DC). The model was validated using experimental data from a 200 kW th pilot plant, achieving a Mean Absolute Error (MAE) below 0.97 ° C for system temperatures and 19.4 l/h for water consumption. An optimization analysis was also performed, demonstrating the potential of the proposed technology to provide adaptive cooling for CSP plants under varying seasonal and operating conditions. For the pilot plant during summer, optimally combining DC and WCT in a parallel series configuration enabled a nearly continuous variation in specific electricity consumption, ranging from 0.06 kW e / kW th in only-DC operation to values up to 90 % lower in only-WCT mode, at a water usage cost of 1.48 l/kWh th . • Physical model to predict the performance of combined cooling systems. • Validated the model experimentally, achieving a MAE of 0.41 ° C for the condensate temperature. • Performed optimal operation analysis across multiple case studies. • Demonstrated the potential of combined cooling for CSP plants using optimization tools.

Energy Conversion and ManagementVol. 348
Universitat de Miguel Hernández d'Elx (ES), Centro de Investigación y Desarrollo (ES), Universidad de Sevilla (ES)
Openalex Percentile: Top 64%
Adsorption and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.