Impact of Stimulus Delivery Method on Music Enjoyment in Cochlear Implant Users
Subjects with unilateral CI demonstrated a preference for EA over DS, which was consistent after retest with randomization. In CI-only conditions (bilateral CI or CI + deaf), subjects had a slight preference for DS or no difference. EA and DS should not be considered equivalent methods of stimulus delivery in the assessment of music enjoyment in unilateral CI recipients.
Authors
- Christian Jung (ORCID: https://orcid.org/0000-0002-7606-2641)
- Hannah Kaufman
- Tiffany P. Hwa (ORCID: https://orcid.org/0000-0002-7274-9366)
- Anil K. Lalwani (ORCID: https://orcid.org/0000-0002-3823-3470)
- Keshav V. Shah (ORCID: https://orcid.org/0000-0003-3315-0665)
- Michael J. Ruckenstein
- Douglas C. Bigelow
- V. Wong
Institutions
- University of Pennsylvania Health System (US)
- New York University (US)
- Columbia University (US)
- University of Pennsylvania (US)
- New York College of Health Professions (US)
Publication Details
- Journal
- Otology & Neurotology
- Published
- 2025-11-17
- DOI
- https://doi.org/10.1097/mao.0000000000004751
- Primary Topic
- Hearing Loss and Rehabilitation
- Type
- article
- Field-Weighted Citation Impact
- 0.00