X-rays on a chip: characterization of a monolithically integrated MEMS X-ray source

• The first MEMS X-ray source integrated on a chip has been demonstrated. • Each parameter of the X-ray radiation can be independently controlled. • Emission currents, vacuum conditions and X-ray spectra are stabile in time. • MEMS X-ray source enables compact XRF analysis with milliwatt-level power use. Miniaturization of X-ray sources developed using MEMS (Micro-electro-mechanical Systems) technology hold significant potential to advance many measurement methods, applied for material analysis, portable diagnostics, and space exploration, through their compactness, low power consumption, and ease of integration. However, it may come true, only if the parameters of the miniature instruments will not be worse than the ones of the classical counterparts. In this work, we present a monolithically integrated MEMS X-ray source that combines a field emission cathode, an electron-optical column, a transmission target, and an integrated ion-sorption pump into a single, self-contained vacuum structure. We demonstrate that the source operates stably and repetitively thanks to the proper choice of the field emission material, device construction as well as thanks to providing and maintaining high vacuum conditions by the use of an integrated micropump. Within the article we characterize the source, and correlate how its parameters (emission stability, voltage control, spot size, vacuum conditions) translate into key properties of the generated X-rays, and how to tune them for different applications, especially for various measurement and analytical methods, especially to X-ray fluorescence (XRF) measurements. Spectral analysis confirms the generation of X-rays with well-controlled intensities and energies from several hundred eV to several tens of keV, including a sharp Si Kα line at 1.71 keV and continuous bremsstrahlung radiation. This fulfils perfectly the requirements of the XRF system.

Authors

Institutions

Publication Details

Journal
Measurement
Published
2025-11-17
DOI
https://doi.org/10.1016/j.measurement.2025.119722
Citations
1
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
1.87
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

X-rays on a chip: characterization of a monolithically integrated MEMS X-ray source

Paweł Urbański, Tomasz Grzebyk
1 citations
Measurement
Particle Detector Development and Performance
1.87
article

X-rays on a chip: characterization of a monolithically integrated MEMS X-ray source

Paweł Urbański, Tomasz Grzebyk
article en
1 citations

Abstract

• The first MEMS X-ray source integrated on a chip has been demonstrated. • Each parameter of the X-ray radiation can be independently controlled. • Emission currents, vacuum conditions and X-ray spectra are stabile in time. • MEMS X-ray source enables compact XRF analysis with milliwatt-level power use. Miniaturization of X-ray sources developed using MEMS (Micro-electro-mechanical Systems) technology hold significant potential to advance many measurement methods, applied for material analysis, portable diagnostics, and space exploration, through their compactness, low power consumption, and ease of integration. However, it may come true, only if the parameters of the miniature instruments will not be worse than the ones of the classical counterparts. In this work, we present a monolithically integrated MEMS X-ray source that combines a field emission cathode, an electron-optical column, a transmission target, and an integrated ion-sorption pump into a single, self-contained vacuum structure. We demonstrate that the source operates stably and repetitively thanks to the proper choice of the field emission material, device construction as well as thanks to providing and maintaining high vacuum conditions by the use of an integrated micropump. Within the article we characterize the source, and correlate how its parameters (emission stability, voltage control, spot size, vacuum conditions) translate into key properties of the generated X-rays, and how to tune them for different applications, especially for various measurement and analytical methods, especially to X-ray fluorescence (XRF) measurements. Spectral analysis confirms the generation of X-rays with well-controlled intensities and energies from several hundred eV to several tens of keV, including a sharp Si Kα line at 1.71 keV and continuous bremsstrahlung radiation. This fulfils perfectly the requirements of the XRF system.

MeasurementVol. 259
Wrocław University of Science and Technology (PL), AGH University of Krakow (PL)
Openalex Percentile: Top 11%
Particle Detector Development and Performance
1.87
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.