Virtual monoenergetic imaging for metal artifact reduction in dental implant surgery using photon-counting detector computed tomography

Purpose: This ex vivo study was performed to determine the optimal energy level for virtual monoenergetic images (VMIs) generated with photon-counting detector computed tomography (PCD-CT) to minimize metal artifacts from dental implants. Materials and Methods: Twelve implants from various manufacturers were placed in 6 pig mandibles and scanned with PCD-CT. VMIs were reconstructed at energy levels from 70 keV to 150 keV in 20-keV increments. Three readers with varying experience qualitatively assessed the image quality, artifact burden, and diagnostic interpretability of periimplant soft and hard tissues using a 5-point discrete visual scale. Objective analyses included quantitative line profile analysis of implant-induced artifacts. Descriptive statistics were calculated, and inter-reader agreement was assessed using percentage agreement and the Krippendorff alpha coefficient. Results: Qualitative analysis demonstrated excellent image quality for VMIs at >_110 keV (median = 5), with minimal artifacts observed at 130-150 keV. In contrast, lower-energy VMIs (70-90 keV) showed inferior performance due to artifact-related limitations in diagnostic interpretability. Inter-reader agreement ranged from moderate to perfect, with perfect reliability (alpha=1) for VMIs >_110 keV. Quantitative line-profile analysis confirmed reduced artifact burden at higher energy levels, particularly for VMIs >= 110keV. Conclusion: VMI at energy levels >_110 keV on PCD-CT reduced dental implant-related metal artifacts and offered excellent image quality, including assessment of both peri-implant soft and hard tissues. These findings suggest that optimized PCD-CT VMI may enhance postoperative follow-up imaging. Future in vivo studies are warranted to validate these findings in clinical practice. (Imaging Sci Dent 20250216)

Authors

Institutions

Publication Details

Journal
Imaging Science in Dentistry
Published
2025-11-17
DOI
https://doi.org/10.5624/isd.20250216
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Virtual monoenergetic imaging for metal artifact reduction in dental implant surgery using photon-counting detector computed tomography

Thomas Sartoretti, Silvio Valdec, Nadin Al‐Haj Husain, Adib Al‐Haj Husain et al.
Imaging Science in Dentistry
Advanced X-ray and CT Imaging
article

Virtual monoenergetic imaging for metal artifact reduction in dental implant surgery using photon-counting detector computed tomography

Thomas Sartoretti, Silvio Valdec, Nadin Al‐Haj Husain, Adib Al‐Haj Husain, Sebastian Winklhofer, Bernd Stadlinger, Harald Essig, Hatem Alkadhi, Victor Mergen
article en

Abstract

Purpose: This ex vivo study was performed to determine the optimal energy level for virtual monoenergetic images (VMIs) generated with photon-counting detector computed tomography (PCD-CT) to minimize metal artifacts from dental implants. Materials and Methods: Twelve implants from various manufacturers were placed in 6 pig mandibles and scanned with PCD-CT. VMIs were reconstructed at energy levels from 70 keV to 150 keV in 20-keV increments. Three readers with varying experience qualitatively assessed the image quality, artifact burden, and diagnostic interpretability of periimplant soft and hard tissues using a 5-point discrete visual scale. Objective analyses included quantitative line profile analysis of implant-induced artifacts. Descriptive statistics were calculated, and inter-reader agreement was assessed using percentage agreement and the Krippendorff alpha coefficient. Results: Qualitative analysis demonstrated excellent image quality for VMIs at >_110 keV (median = 5), with minimal artifacts observed at 130-150 keV. In contrast, lower-energy VMIs (70-90 keV) showed inferior performance due to artifact-related limitations in diagnostic interpretability. Inter-reader agreement ranged from moderate to perfect, with perfect reliability (alpha=1) for VMIs >_110 keV. Quantitative line-profile analysis confirmed reduced artifact burden at higher energy levels, particularly for VMIs >= 110keV. Conclusion: VMI at energy levels >_110 keV on PCD-CT reduced dental implant-related metal artifacts and offered excellent image quality, including assessment of both peri-implant soft and hard tissues. These findings suggest that optimized PCD-CT VMI may enhance postoperative follow-up imaging. Future in vivo studies are warranted to validate these findings in clinical practice. (Imaging Sci Dent 20250216)

Imaging Science in DentistryVol. 56(1)
University of Bern (CH), University of Zurich (CH), Maastricht University Medical Centre (NL), University Hospital of Zurich (CH)
Openalex Percentile: Top 66%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.