Impact of advanced noise reduction algorithms on the diagnostic accuracy of vertical root fractures in cone-beam computed tomography: An evaluation of the influence of intracanal post types

Purpose: Vertical root fractures (VRFs) remain a major diagnostic challenge in endodontics due to image noise and artifacts in cone-beam computed tomography (CBCT), particularly those caused by intracanal posts.This study evaluated the effect of an advanced noise reduction (ANR) algorithm on CBCT performance in detecting VRFs in maxillary second premolars and examined how different post materials influenced diagnostic outcomes.Materials and Methods: Seventy extracted maxillary second premolars with single canals were divided into 5 groups according to post material (cast, fiberglass, titanium, stainless steel, and brass).VRFs were induced in half of the specimens using a universal testing machine under standardized conditions.CBCT scans were obtained using a Carestream 9600 device with fixed parameters, both with and without ANR.Two experienced radiologists independently evaluated the images using a 5-point scale.Sensitivity, specificity, predictive values, and interobserver agreement were analyzed using SPSS version 21 (IBM Corp., Armonk, NY, USA).Results: The application of ANR increased overall sensitivity and interobserver agreement compared with conventional images.Specificity varied by post material: fiberglass posts demonstrated the highest diagnostic accuracy, while stainless steel and brass produced stronger artifacts and lower sensitivity. Conclusion:Incorporating ANR into CBCT imaging improves VRF detection by improving sensitivity and observer consistency, especially in cases with minimal metallic interference.These findings highlight the clinical benefits of ANR and support further research integrating noise and metal artifact reduction techniques with artificial intelligence to optimize diagnostic precision.

Authors

Institutions

Publication Details

Journal
Imaging Science in Dentistry
Published
2025-11-17
DOI
https://doi.org/10.5624/isd.20250122
Primary Topic
Dental Radiography and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of advanced noise reduction algorithms on the diagnostic accuracy of vertical root fractures in cone-beam computed tomography: An evaluation of the influence of intracanal post types

Leili Tapak, Abbas Shokri, Mohammad Mahdi Maleki, Foozie Zahedi et al.
Imaging Science in Dentistry
Dental Radiography and Imaging
article

Impact of advanced noise reduction algorithms on the diagnostic accuracy of vertical root fractures in cone-beam computed tomography: An evaluation of the influence of intracanal post types

Leili Tapak, Abbas Shokri, Mohammad Mahdi Maleki, Foozie Zahedi, Pouya Hassani
article en

Abstract

Purpose: Vertical root fractures (VRFs) remain a major diagnostic challenge in endodontics due to image noise and artifacts in cone-beam computed tomography (CBCT), particularly those caused by intracanal posts.This study evaluated the effect of an advanced noise reduction (ANR) algorithm on CBCT performance in detecting VRFs in maxillary second premolars and examined how different post materials influenced diagnostic outcomes.Materials and Methods: Seventy extracted maxillary second premolars with single canals were divided into 5 groups according to post material (cast, fiberglass, titanium, stainless steel, and brass).VRFs were induced in half of the specimens using a universal testing machine under standardized conditions.CBCT scans were obtained using a Carestream 9600 device with fixed parameters, both with and without ANR.Two experienced radiologists independently evaluated the images using a 5-point scale.Sensitivity, specificity, predictive values, and interobserver agreement were analyzed using SPSS version 21 (IBM Corp., Armonk, NY, USA).Results: The application of ANR increased overall sensitivity and interobserver agreement compared with conventional images.Specificity varied by post material: fiberglass posts demonstrated the highest diagnostic accuracy, while stainless steel and brass produced stronger artifacts and lower sensitivity. Conclusion:Incorporating ANR into CBCT imaging improves VRF detection by improving sensitivity and observer consistency, especially in cases with minimal metallic interference.These findings highlight the clinical benefits of ANR and support further research integrating noise and metal artifact reduction techniques with artificial intelligence to optimize diagnostic precision.

Imaging Science in DentistryVol. 56(1)
Hamedan University of Medical Sciences (IR)
Openalex Percentile: Top 51%
Dental Radiography and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.