Identification of Legionella anisa, Legionella longbeachae and Legionella pneumophila using MALDI-TOF MS: A method validation study with environmental isolates

Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) allows species-level microbial identification quickly and cost-effectively. The aim of this study was to validate MALDI-TOF MS for the identification of Legionella anisa, Legionella longbeachae and Legionella pneumophila and to examine whether incubation time or sample preparation method affect identification results. Environmental Legionella strains and ATCC reference strains were used in the study. The strains underwent 16S rRNA sequencing and latex agglutination and fluorescence tests to which MALDI-TOF MS results were compared. The strains, incubated for 24 and 48 h, were analysed with MALDI-TOF MS using direct transfer and extraction methods. Following performance characteristics were calculated from the results: sensitivity, specificity, relative accuracy, predictive values, repeatability and reproducibility. Species-level identification was achieved for 63 out of the 69 environmental and reference strains regardless of incubation time or preparation method. MALDI-TOF MS proved to be very specific (100 %) and sensitive (94.6-100 %) to the Legionella species analysed. With the extraction method, incubation time had a statistically significant, but species-dependent effect on the interpretative criteria, i.e. score values, in all species studied. No significant difference in any of the species' score values was found between the direct transfer and extraction methods with 24 h incubation. MALDI-TOF MS score values showed high repeatability (std 0.01-0.23) and reproducibility (std 0.02-0.18) for all Legionella species analysed. Based on the results, MALDI-TOF MS suits well for the analysis of environmental Legionella strains already after 24 h of incubation and using direct transfer method.

Authors

Institutions

Publication Details

Journal
Journal of Microbiological Methods
Published
2025-11-17
DOI
https://doi.org/10.1016/j.mimet.2025.107330
Citations
1
Primary Topic
Bacterial Identification and Susceptibility Testing
Type
article
Field-Weighted Citation Impact
1.32
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Identification of Legionella anisa, Legionella longbeachae and Legionella pneumophila using MALDI-TOF MS: A method validation study with environmental isolates

Pekka Matias Rossi, Silja Mentula, Jenni Ikonen, Marjo Niittynen et al.
1 citations
Journal of Microbiological Methods
Bacterial Identification and Susceptibility Testing
1.32
article

Identification of Legionella anisa, Legionella longbeachae and Legionella pneumophila using MALDI-TOF MS: A method validation study with environmental isolates

Pekka Matias Rossi, Silja Mentula, Jenni Ikonen, Marjo Niittynen, Ilkka T. Miettinen, Ellinoora Savonen
article en
1 citations

Abstract

Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) allows species-level microbial identification quickly and cost-effectively. The aim of this study was to validate MALDI-TOF MS for the identification of Legionella anisa, Legionella longbeachae and Legionella pneumophila and to examine whether incubation time or sample preparation method affect identification results. Environmental Legionella strains and ATCC reference strains were used in the study. The strains underwent 16S rRNA sequencing and latex agglutination and fluorescence tests to which MALDI-TOF MS results were compared. The strains, incubated for 24 and 48 h, were analysed with MALDI-TOF MS using direct transfer and extraction methods. Following performance characteristics were calculated from the results: sensitivity, specificity, relative accuracy, predictive values, repeatability and reproducibility. Species-level identification was achieved for 63 out of the 69 environmental and reference strains regardless of incubation time or preparation method. MALDI-TOF MS proved to be very specific (100 %) and sensitive (94.6-100 %) to the Legionella species analysed. With the extraction method, incubation time had a statistically significant, but species-dependent effect on the interpretative criteria, i.e. score values, in all species studied. No significant difference in any of the species' score values was found between the direct transfer and extraction methods with 24 h incubation. MALDI-TOF MS score values showed high repeatability (std 0.01-0.23) and reproducibility (std 0.02-0.18) for all Legionella species analysed. Based on the results, MALDI-TOF MS suits well for the analysis of environmental Legionella strains already after 24 h of incubation and using direct transfer method.

Journal of Microbiological MethodsVol. 240
Finnish Institute for Health and Welfare (FI), University of Oulu (FI)
Openalex Percentile: Top 14%
Bacterial Identification and Susceptibility Testing
1.32
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.