The rapid advancement of wearable technologies has facilitated the acquisition of myoelectric signals, which are increasingly used as input for machine learning (ML) architectures to recognize human motion. However, the technical specifications of sensors and the experimental setup can significantly affect signal quality, potentially reducing the reliability of motor command recognition. This study investigates how signal quantization (ADC resolution) and sampling frequency influence the performance of myoelectric hand gesture recognition. Surface EMG was recorded with an armband during 20 gestures performed by 10 healthy subjects. Three acquisition settings were tested: 8-bit/500 Hz, 8-bit/1000 Hz, and 12-bit/500 Hz. A time-domain feature set was extracted and used to train three classifiers: linear discriminant analysis (LDA), linear support vector machine (SVM), and quadratic SVM (SVMQ). Results show that higher sampling frequency consistently improved classification accuracy, both with the full armband configuration and with a reduced sensor setup (4 channels). The linear SVM trained with the complete feature set achieved the best performance, with accuracy up to 90% using all sensors and around 80% with the minimal configuration. Even when trained with a single feature, such as mean absolute value or waveform length, the full configuration yielded accuracy above 80% across conditions. In contrast, ADC resolution had only a marginal impact on performance. Overall, the findings indicate that appropriate feature selection and sensor configuration can mitigate the effects of lower sampling rates, offering practical trade-offs between recognition accuracy and computational efficiency in wearable EMG-based systems. • Smart armbands capture EMG signals for decoding hand movements. • Hand-crafted features from EMG signals can efficiently be used for gesture recognition. • Device specifications influence signal quality and study reliability. • Sampling rate is crucial to preserve EMG information. • ADC resolution shows minimal effect on classification accuracy.

Authors

Institutions

Publication Details

Journal
Biomedical Signal Processing and Control
Published
2025-11-17
DOI
https://doi.org/10.1016/j.bspc.2025.109035
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of sampling frequency and signal quantization on myoelectric-based hand gesture recognition

Andrea Tigrini, Mara Scattolini, Alessandro Mengarelli, Sandro Fioretti et al.
Biomedical Signal Processing and Control
Muscle activation and electromyography studies
article

Impact of sampling frequency and signal quantization on myoelectric-based hand gesture recognition

Andrea Tigrini, Mara Scattolini, Alessandro Mengarelli, Sandro Fioretti, Federica Verdini, Laura Burattini, Rami Mobarak
article en

Abstract

The rapid advancement of wearable technologies has facilitated the acquisition of myoelectric signals, which are increasingly used as input for machine learning (ML) architectures to recognize human motion. However, the technical specifications of sensors and the experimental setup can significantly affect signal quality, potentially reducing the reliability of motor command recognition. This study investigates how signal quantization (ADC resolution) and sampling frequency influence the performance of myoelectric hand gesture recognition. Surface EMG was recorded with an armband during 20 gestures performed by 10 healthy subjects. Three acquisition settings were tested: 8-bit/500 Hz, 8-bit/1000 Hz, and 12-bit/500 Hz. A time-domain feature set was extracted and used to train three classifiers: linear discriminant analysis (LDA), linear support vector machine (SVM), and quadratic SVM (SVMQ). Results show that higher sampling frequency consistently improved classification accuracy, both with the full armband configuration and with a reduced sensor setup (4 channels). The linear SVM trained with the complete feature set achieved the best performance, with accuracy up to 90% using all sensors and around 80% with the minimal configuration. Even when trained with a single feature, such as mean absolute value or waveform length, the full configuration yielded accuracy above 80% across conditions. In contrast, ADC resolution had only a marginal impact on performance. Overall, the findings indicate that appropriate feature selection and sensor configuration can mitigate the effects of lower sampling rates, offering practical trade-offs between recognition accuracy and computational efficiency in wearable EMG-based systems. • Smart armbands capture EMG signals for decoding hand movements. • Hand-crafted features from EMG signals can efficiently be used for gesture recognition. • Device specifications influence signal quality and study reliability. • Sampling rate is crucial to preserve EMG information. • ADC resolution shows minimal effect on classification accuracy.

Biomedical Signal Processing and ControlVol. 113
Marche Polytechnic University (IT), Università degli Studi eCampus (IT)
Openalex Percentile: Top 66%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.