Ultrasonically synthesized Cu/Ag/Zn nanocomposite coatings for antibacterial and antibiofilm applications in urological devices

Catheter-associated urinary tract infections (CAUTIs) pose a persistent clinical challenge due to bacterial colonization and biofilm formation on indwelling urological devices. This study investigates the efficacy of Cu/Ag/Zn trimetallic nanocomposites (TMNCs) as antimicrobial coatings for urinary catheters, synthesized via a green, ultrasonic-autoclave-assisted method. The nanocomposites were thoroughly characterized using X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), Fourier-transform infrared spectroscopy (FTIR), Raman spectroscopy, thermogravimetric analysis (TGA), Brunauer-Emmett-Teller (BET) surface area analysis, and field emission scanning electron microscopy (FESEM) to confirm their mesoporous, crystalline, uniformly distributed, and thermally stable nanoparticles. An optimized ultrasonic embedding technique was employed to uniformly coat TMNCs onto commercial urinary catheters, ensuring strong adhesion and consistent coverage. Antibacterial assays demonstrated concentration-dependent inhibition zones, reaching up to 21.5 mm for Escherichia coli and 24.0 mm for Staphylococcus aureus. Minimum inhibitory concentration (MIC) tests confirmed potent bactericidal activity, with MIC values of 32 µg/mL for E. coli and 64 µg/mL for S. aureus. Anti-biofilm assessments revealed that TMNCs matched or outperformed the efficacy of vancomycin, achieving up to 86.12 % inhibition for S. aureus and 73.59 % for E. coli at 2 × MIC. Cytotoxicity testing using U87 glioblastoma cells indicated good biocompatibility, with over 79 % cell viability at 0.1 mg/mL, followed by a dose-dependent decline at higher concentrations. Long-term stability studies conducted over 60 days under varied storage conditions confirmed the photothermal and colloidal stability of the TMNCs. In conclusion, Cu/Ag/Zn TMNC-coated urinary catheters demonstrated excellent antibacterial and anti-biofilm properties, biocompatibility, and long-term stability. These multi-functional coatings present a promising strategy for reducing CAUTI incidence and improving patient safety and clinical outcomes in urological applications.

Authors

Institutions

Publication Details

Journal
Ultrasonics Sonochemistry
Published
2025-11-13
DOI
https://doi.org/10.1016/j.ultsonch.2025.107674
Primary Topic
Urinary Tract Infections Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultrasonically synthesized Cu/Ag/Zn nanocomposite coatings for antibacterial and antibiofilm applications in urological devices

Y. Chen, Zhongmin Li, Luo Chun, Houhong Wang et al.
Ultrasonics Sonochemistry
Urinary Tract Infections Management
article

Ultrasonically synthesized Cu/Ag/Zn nanocomposite coatings for antibacterial and antibiofilm applications in urological devices

Y. Chen, Zhongmin Li, Luo Chun, Houhong Wang, Peng Yan, Keshuai Shang, Wei Chen, Weilin Wang
article en

Abstract

Catheter-associated urinary tract infections (CAUTIs) pose a persistent clinical challenge due to bacterial colonization and biofilm formation on indwelling urological devices. This study investigates the efficacy of Cu/Ag/Zn trimetallic nanocomposites (TMNCs) as antimicrobial coatings for urinary catheters, synthesized via a green, ultrasonic-autoclave-assisted method. The nanocomposites were thoroughly characterized using X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), Fourier-transform infrared spectroscopy (FTIR), Raman spectroscopy, thermogravimetric analysis (TGA), Brunauer-Emmett-Teller (BET) surface area analysis, and field emission scanning electron microscopy (FESEM) to confirm their mesoporous, crystalline, uniformly distributed, and thermally stable nanoparticles. An optimized ultrasonic embedding technique was employed to uniformly coat TMNCs onto commercial urinary catheters, ensuring strong adhesion and consistent coverage. Antibacterial assays demonstrated concentration-dependent inhibition zones, reaching up to 21.5 mm for Escherichia coli and 24.0 mm for Staphylococcus aureus. Minimum inhibitory concentration (MIC) tests confirmed potent bactericidal activity, with MIC values of 32 µg/mL for E. coli and 64 µg/mL for S. aureus. Anti-biofilm assessments revealed that TMNCs matched or outperformed the efficacy of vancomycin, achieving up to 86.12 % inhibition for S. aureus and 73.59 % for E. coli at 2 × MIC. Cytotoxicity testing using U87 glioblastoma cells indicated good biocompatibility, with over 79 % cell viability at 0.1 mg/mL, followed by a dose-dependent decline at higher concentrations. Long-term stability studies conducted over 60 days under varied storage conditions confirmed the photothermal and colloidal stability of the TMNCs. In conclusion, Cu/Ag/Zn TMNC-coated urinary catheters demonstrated excellent antibacterial and anti-biofilm properties, biocompatibility, and long-term stability. These multi-functional coatings present a promising strategy for reducing CAUTI incidence and improving patient safety and clinical outcomes in urological applications.

Ultrasonics SonochemistryVol. 123
Fujian Normal University (CN), Fuyang Normal University (CN), Anhui Medical University (CN), Affiliated Hospital of Hangzhou Normal University (CN), First Affiliated Hospital of Anhui Medical University (CN)
Openalex Percentile: Top 55%
Urinary Tract Infections Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.