The CEPC Clock Issue and Fine-tuning of the Circumference

The CEPC clock issue is related with the RF frequency coordination between the various accelerator systems and may affect the operation modes of both the accelerator and the detector. The timing structure of CEPC has been restudied with the collaboration of the accelerator team and the detector team. After discussions between two sides, the CEPC bunch structure is set such that the spacings between adjacent bunches in any CEPC operation mode are integer numbers of 23.08 ns. The master CEPC clock will be provided by the accelerator to the detector systems with a frequency of 43.33 MHz, synchronous to the beam. The CEPC detector system relies on the clock to sample physics signal at the right time. It was found that if the circumference of CEPC is slightly changed to 99955.42 m, the detector would benefit more for the first 10-year operation.

Authors

Publication Details

Journal
International Journal of Modern Physics A
Published
2026-09-11
DOI
https://doi.org/10.1142/s0217751x26410071
Primary Topic
Particle Accelerators and Free-Electron Lasers
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

The CEPC Clock Issue and Fine-tuning of the Circumference

Zhi Ma, J.H. Wang, Dou Wang, Jiyuan Zhai et al.
International Journal of Modern Physics A
Particle Accelerators and Free-Electron Lasers
article

The CEPC Clock Issue and Fine-tuning of the Circumference

Zhi Ma, J.H. Wang, Dou Wang, Jiyuan Zhai, J M Ye, Jie Gao, Yanping Li, Yiwei Wang, X J Wang, Dapeng Jin, Ge Lei, Xiaohao Cui, Jun Hu, Cai Meng
article en

Abstract

The CEPC clock issue is related with the RF frequency coordination between the various accelerator systems and may affect the operation modes of both the accelerator and the detector. The timing structure of CEPC has been restudied with the collaboration of the accelerator team and the detector team. After discussions between two sides, the CEPC bunch structure is set such that the spacings between adjacent bunches in any CEPC operation mode are integer numbers of 23.08 ns. The master CEPC clock will be provided by the accelerator to the detector systems with a frequency of 43.33 MHz, synchronous to the beam. The CEPC detector system relies on the clock to sample physics signal at the right time. It was found that if the circumference of CEPC is slightly changed to 99955.42 m, the detector would benefit more for the first 10-year operation.

International Journal of Modern Physics A
Openalex Percentile: Top 99%
Particle Accelerators and Free-Electron Lasers
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The CEPC Clock Issue and Fine-tuning of the Circumference — Zhi Ma, J.H. Wang, et al. · International Journal of Modern Physics A (2026) | TGRS Research Map | TGRS