Study on the structural catastrophe mechanism and disaster mitigation strategies of a double-compartment underground utility tunnel under the creep-slip dislocation of reverse fault

Fault creep-slip dislocation and seismic effects can cause significant damage to underground structures that are shallowly buried and cross faults and their overlying soils. This study investigates the seismic performance of a segmental double-compartment utility tunnel crossing a 45° reverse fault. Through a 1:30 scale model test incorporating a novel disaster mitigation strategy—flexible joints and damping layers—we assessed the structure's real-time response to fault creep. This approach enables the elucidation of the disaster mechanism and the assessment of the disaster mitigation effect of setting up protection under the fault creep-slip dislocation. The findings indicate that flexible joints are more effective in dissipating the energy and forced displacement generated by fault creep-slip misalignment. This, in turn, reduces the bending-shear composite action applied to the structure. The adjacent sections of the segmental lining structure exhibit minimal degradation, with local damage restricted to the joints of blocks C-E. This mitigates the risk of complete structural collapse. A discernible displacement change has been identified in the underground utility tunnel structure situated within the Hanging Wall area. The internal force response of the double-compartment underground utility tunnel structure in close proximity to the fault surface is noteworthy, particularly the damage observed in the underground utility tunnel structure within the range of 70–120 cm, which should be regarded as a critical defensive area. Subsequent to the execution of the inverse fault misalignment, the double-compartment underground utility tunnel structure becomes vulnerable to tensile and compressive damage. The predominant forms of cracking damage include cracks, inter-ring misalignments and the spalling off of blocks. The occurrence of fault misalignment gives rise to the movement of the overlying soil layer towards the surface. This process ultimately results in the formation of through cracks and substantial damage to the surface at a specific depth within the hanging wall. The deformation of the soil can be classified into three distinct zones: the hanging wall stability zone, the deformation zone, and the footwall stability zone. Ensuring the stability of the ground structure is imperative. It is therefore imperative to avoid these zones as much as possible. Moreover, it is recommended that a safe distance be maintained from the deformation zone on the surface. The deformation zone of the overlying soil layer is subdivided into three distinct zones. The aforementioned zones are designated as Zone I, Zone II and Zone III. The perimeter of the soil body in Zone II is delineated by an inverted triangular configuration, which is designated as the shearing zone. It has been demonstrated that the implementation of flexible joints can effectively enhance the fracture-resistant performance of underground structures by safeguarding the passage following an earthquake.

Authors

Institutions

Publication Details

Journal
Alexandria Engineering Journal
Published
2025-11-15
DOI
https://doi.org/10.1016/j.aej.2025.11.006
Citations
2
Primary Topic
Geotechnical Engineering and Underground Structures
Type
article
Field-Weighted Citation Impact
1.91
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on the structural catastrophe mechanism and disaster mitigation strategies of a double-compartment underground utility tunnel under the creep-slip dislocation of reverse fault

Jiangong Liu, Cong Zhao, Lianjin Tao, Zhigang Wang et al.
2 citations
Alexandria Engineering Journal
Geotechnical Engineering and Underground Structures
1.91
article

Study on the structural catastrophe mechanism and disaster mitigation strategies of a double-compartment underground utility tunnel under the creep-slip dislocation of reverse fault

Jiangong Liu, Cong Zhao, Lianjin Tao, Zhigang Wang, Sanqiang Yang
article en
2 citations

Abstract

Fault creep-slip dislocation and seismic effects can cause significant damage to underground structures that are shallowly buried and cross faults and their overlying soils. This study investigates the seismic performance of a segmental double-compartment utility tunnel crossing a 45° reverse fault. Through a 1:30 scale model test incorporating a novel disaster mitigation strategy—flexible joints and damping layers—we assessed the structure's real-time response to fault creep. This approach enables the elucidation of the disaster mechanism and the assessment of the disaster mitigation effect of setting up protection under the fault creep-slip dislocation. The findings indicate that flexible joints are more effective in dissipating the energy and forced displacement generated by fault creep-slip misalignment. This, in turn, reduces the bending-shear composite action applied to the structure. The adjacent sections of the segmental lining structure exhibit minimal degradation, with local damage restricted to the joints of blocks C-E. This mitigates the risk of complete structural collapse. A discernible displacement change has been identified in the underground utility tunnel structure situated within the Hanging Wall area. The internal force response of the double-compartment underground utility tunnel structure in close proximity to the fault surface is noteworthy, particularly the damage observed in the underground utility tunnel structure within the range of 70–120 cm, which should be regarded as a critical defensive area. Subsequent to the execution of the inverse fault misalignment, the double-compartment underground utility tunnel structure becomes vulnerable to tensile and compressive damage. The predominant forms of cracking damage include cracks, inter-ring misalignments and the spalling off of blocks. The occurrence of fault misalignment gives rise to the movement of the overlying soil layer towards the surface. This process ultimately results in the formation of through cracks and substantial damage to the surface at a specific depth within the hanging wall. The deformation of the soil can be classified into three distinct zones: the hanging wall stability zone, the deformation zone, and the footwall stability zone. Ensuring the stability of the ground structure is imperative. It is therefore imperative to avoid these zones as much as possible. Moreover, it is recommended that a safe distance be maintained from the deformation zone on the surface. The deformation zone of the overlying soil layer is subdivided into three distinct zones. The aforementioned zones are designated as Zone I, Zone II and Zone III. The perimeter of the soil body in Zone II is delineated by an inverted triangular configuration, which is designated as the shearing zone. It has been demonstrated that the implementation of flexible joints can effectively enhance the fracture-resistant performance of underground structures by safeguarding the passage following an earthquake.

Alexandria Engineering JournalVol. 133
Beijing University of Technology (CN), Hebei University (CN)
Openalex Percentile: Top 13%
Geotechnical Engineering and Underground Structures
1.91
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.