Development and validation of a robust QbD-guided (RP-HPLC) analytical technique for quantifying coenzyme Q10 in pharmaceutical dosage form

Background: Coenzyme Q10 (CoQ10) is a lipophilic antioxidant that contributes to mitochondrial energy production but poses analytical challenges due to low solubility and oxidative sensitivity. An accurate and validated method is essential to ensure quality control of its pharmaceutical dosage forms. Methodology: A reverse-phase high-performance liquid chromatography (RP-HPLC) method was designed using Quality by Design (QbD) principles. A Central Composite Design was employed to study the influence of critical parameters, including flow rate, gradient time, and mobile phase ratio. Separation was carried out on a Gemini C18 column (250 × 4.6 mm, 5 µm) with gradient elution using ethyl acetate: acetonitrile (50:50) and methanol: acetonitrile (80:20) containing 0.1% ammonia. The method was validated in accordance with ICH-Q2 (R1) guidelines. Results: The optimized conditions yielded a sharp CoQ10 peak at approximately 12.9 minutes with high resolution (Rs > 36), theoretical plates (~33,800), and acceptable tailing (≤1.3). Linearity was established over 2.5–200 µg/mL (r² = 0.9997). Accuracy ranged from 99.2–101.4%, precision was within %RSD ≤1.5%, and robustness was demonstrated under deliberate variations. Discussion: The method proved capable of consistently quantifying CoQ10 with superior specificity and sensitivity. Application to commercial soft gel formulations confirmed assay values at 99.5% of the label claim, meeting pharmacopeial standards. Conclusion: This QbD-based RP-HPLC method offers a validated, reproducible, and regulation-compliant strategy for the quality control and stability assessment of CoQ10 dosage forms, with potential extension to similar pharmaceutical compounds.

Authors

Institutions

Publication Details

Journal
Journal of Applied Pharmaceutical Research
Published
2025-10-31
DOI
https://doi.org/10.69857/joapr.v13i5.1696
Citations
1
Primary Topic
Coenzyme Q10 studies and effects
Type
article
Field-Weighted Citation Impact
0.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and validation of a robust QbD-guided (RP-HPLC) analytical technique for quantifying coenzyme Q10 in pharmaceutical dosage form

Vishal Pathak, Phool Chandra, Bhupendra Singh
1 citations
Journal of Applied Pharmaceutical Research
Coenzyme Q10 studies and effects
0.81
article

Development and validation of a robust QbD-guided (RP-HPLC) analytical technique for quantifying coenzyme Q10 in pharmaceutical dosage form

Vishal Pathak, Phool Chandra, Bhupendra Singh
article en
1 citations

Abstract

Background: Coenzyme Q10 (CoQ10) is a lipophilic antioxidant that contributes to mitochondrial energy production but poses analytical challenges due to low solubility and oxidative sensitivity. An accurate and validated method is essential to ensure quality control of its pharmaceutical dosage forms. Methodology: A reverse-phase high-performance liquid chromatography (RP-HPLC) method was designed using Quality by Design (QbD) principles. A Central Composite Design was employed to study the influence of critical parameters, including flow rate, gradient time, and mobile phase ratio. Separation was carried out on a Gemini C18 column (250 × 4.6 mm, 5 µm) with gradient elution using ethyl acetate: acetonitrile (50:50) and methanol: acetonitrile (80:20) containing 0.1% ammonia. The method was validated in accordance with ICH-Q2 (R1) guidelines. Results: The optimized conditions yielded a sharp CoQ10 peak at approximately 12.9 minutes with high resolution (Rs > 36), theoretical plates (~33,800), and acceptable tailing (≤1.3). Linearity was established over 2.5–200 µg/mL (r² = 0.9997). Accuracy ranged from 99.2–101.4%, precision was within %RSD ≤1.5%, and robustness was demonstrated under deliberate variations. Discussion: The method proved capable of consistently quantifying CoQ10 with superior specificity and sensitivity. Application to commercial soft gel formulations confirmed assay values at 99.5% of the label claim, meeting pharmacopeial standards. Conclusion: This QbD-based RP-HPLC method offers a validated, reproducible, and regulation-compliant strategy for the quality control and stability assessment of CoQ10 dosage forms, with potential extension to similar pharmaceutical compounds.

Journal of Applied Pharmaceutical ResearchVol. 13(5)
Teerthanker Mahaveer University (IN), CT Group Of Institutions (IN)
Openalex Percentile: Top 22%
Coenzyme Q10 studies and effects
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.