Structure Design and Experimental Study on a Shape Memory Alloy Based Negative Pressure Sampling Capsule

Abstract This study aims to introduce a wireless, remotely triggered biopsy capsule based on shape memory alloy (SMA). This capsule utilizes the negative pressure suction principle to achieve liquid sampling within the digestive tract. The proposed capsule is designed with an SMA spring-driven sampling trigger mechanism. An external magnetic field directs the capsule to the sampling area and aligns the sampling port with the sampling liquid. A Bluetooth signal is then sent and energizes the SMA spring, causing deformation and generating negative pressure for liquid sampling. The capsule prototype has dimensions of ø 15.0 mm × 30.0 mm. Both simulation and in vitro experiments have been carried out. Results showed that the proposed capsule has a rapid response time of 1.4 s and can sample liquids with viscosities ranging from 0.7 mPa·s to 100 mPa·s with the maximum sampling volume around 0.2 mL. Furthermore, the capsule's sealing performance has also been verified. The experimental results indicate that the proposed capsule can achieve Bluetooth remote-triggered liquid sampling in the digestive tract and satisfy the clinical requirements.

Authors

Institutions

Publication Details

Journal
Journal of Medical Devices
Published
2025-11-15
DOI
https://doi.org/10.1115/1.4070417
Primary Topic
Soft Robotics and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Structure Design and Experimental Study on a Shape Memory Alloy Based Negative Pressure Sampling Capsule

T.L. Yang, Jiaole Wang, Shuang Song
Journal of Medical Devices
Soft Robotics and Applications
article

Structure Design and Experimental Study on a Shape Memory Alloy Based Negative Pressure Sampling Capsule

T.L. Yang, Jiaole Wang, Shuang Song
article en

Abstract

Abstract This study aims to introduce a wireless, remotely triggered biopsy capsule based on shape memory alloy (SMA). This capsule utilizes the negative pressure suction principle to achieve liquid sampling within the digestive tract. The proposed capsule is designed with an SMA spring-driven sampling trigger mechanism. An external magnetic field directs the capsule to the sampling area and aligns the sampling port with the sampling liquid. A Bluetooth signal is then sent and energizes the SMA spring, causing deformation and generating negative pressure for liquid sampling. The capsule prototype has dimensions of ø 15.0 mm × 30.0 mm. Both simulation and in vitro experiments have been carried out. Results showed that the proposed capsule has a rapid response time of 1.4 s and can sample liquids with viscosities ranging from 0.7 mPa·s to 100 mPa·s with the maximum sampling volume around 0.2 mL. Furthermore, the capsule's sealing performance has also been verified. The experimental results indicate that the proposed capsule can achieve Bluetooth remote-triggered liquid sampling in the digestive tract and satisfy the clinical requirements.

Journal of Medical DevicesVol. 20(2)
University Town of Shenzhen (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 66%
Soft Robotics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.