End-to-End Hardware Modeling and Sensitivity Optimization of Photoacoustic Signal Readout Chains

The sensitivity of the acoustic detection subsystem in photoacoustic imaging (PAI) critically affects image quality. However, previous studies often focused only on front-end acoustic components or back-end electronic components, overlooking end-to-end coupling among the transducer, cable, and receiver. This work develops a complete analytical model for system-level sensitivity optimization based on the Krimholtz, Leedom, and Matthaei (KLM) model. The KLM model is rederived from first principles of linear piezoelectric constitutive equations, 1D wave equations and transmission line theory to clarify its physical basis and applicable conditions. By encapsulating the acoustic components into a controlled voltage source and extending the model to include lumped-parameter representations of cable and receiver, an end-to-end equivalent circuit is established. Analytical expressions for the system transfer functions are derived, revealing the coupling effects among key parameters such as transducer element area (EA), cable length (CL), and receiver impedance (RI). Experimental results validate the model with an average error below 5%. Additionally, a low-frequency tailing phenomenon arising from exceeding the 1D vibration assumption is identified and analyzed, illustrating the importance of understanding the model's applicable conditions and providing a potential pathway for artifact suppression. This work offers a comprehensive framework for optimizing detection sensitivity and improving image fidelity in PAI systems.

Authors

Publication Details

Journal
Biomedical Optics Express
Published
2026-05-18
DOI
https://doi.org/10.1364/boe.599556
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

End-to-End Hardware Modeling and Sensitivity Optimization of Photoacoustic Signal Readout Chains

Yiqi Cai, Handi Deng, Cheng Ma, Wei Yang
Biomedical Optics Express
Photoacoustic and Ultrasonic Imaging
article

End-to-End Hardware Modeling and Sensitivity Optimization of Photoacoustic Signal Readout Chains

Yiqi Cai, Handi Deng, Cheng Ma, Wei Yang
article en

Abstract

The sensitivity of the acoustic detection subsystem in photoacoustic imaging (PAI) critically affects image quality. However, previous studies often focused only on front-end acoustic components or back-end electronic components, overlooking end-to-end coupling among the transducer, cable, and receiver. This work develops a complete analytical model for system-level sensitivity optimization based on the Krimholtz, Leedom, and Matthaei (KLM) model. The KLM model is rederived from first principles of linear piezoelectric constitutive equations, 1D wave equations and transmission line theory to clarify its physical basis and applicable conditions. By encapsulating the acoustic components into a controlled voltage source and extending the model to include lumped-parameter representations of cable and receiver, an end-to-end equivalent circuit is established. Analytical expressions for the system transfer functions are derived, revealing the coupling effects among key parameters such as transducer element area (EA), cable length (CL), and receiver impedance (RI). Experimental results validate the model with an average error below 5%. Additionally, a low-frequency tailing phenomenon arising from exceeding the 1D vibration assumption is identified and analyzed, illustrating the importance of understanding the model's applicable conditions and providing a potential pathway for artifact suppression. This work offers a comprehensive framework for optimizing detection sensitivity and improving image fidelity in PAI systems.

Biomedical Optics Express
Tsinghua University
Openalex Percentile: Top 100%
Photoacoustic and Ultrasonic Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.