Superhot (> 30 MK) flare observations with STIX: Joint spectral fitting

Context. Spectroscopic analysis of large flares (> X1) in the hard X-ray (HXR) range offers unique insights into the hottest (> 30 MK) flare plasma, the so-called superhot thermal component. To manage the high count rates in large flares, an attenuator is typically placed in front of the HXR detectors. However, this significantly limits the spectral diagnostic capabilities at lower energies, and consequently, it restricts the analysis of the lower temperatures in flares. Aims. The Spectrometer/Telescope for Imaging X-rays (STIX) on board the Solar Orbiter mission was designed to observe solar flares in HXRs. The imaging detectors use an attenuator during periods of high flux. In contrast, the background (BKG) detector of STIX is never covered by the attenuator and is therefore dedicated to measuring the unattenuated flux using differently sized apertures placed in front of the detector. We aim to demonstrate that joint spectral fitting using different detector configurations of STIX allows us to reliably diagnose both the hot and the superhot components in large flares. Methods. We jointly fit the HXR spectra of the STIX BKG detector and the STIX imaging detectors using the SUNKIT-SPEX software package to determine the spectral parameters of both the hot and superhot thermal components in solar flares. Results. Using joint fitting on 32 STIX flares, we corroborated that for GOES X-class flares the HXR spectrum is better represented by two thermal components instead of an isothermal component. At the temperature peak time, the superhot HXR flux above ∼15 keV is typically stronger than the hot HXR flux. The GOES long-wavelength channel is dominated by the hot component with a superhot contribution up to 10%. Conclusions. This paper demonstrates that joint spectral fitting of the same detector type with different attenuation schemes is a simple and powerful method of monitoring multithermal flare plasma.

Authors

Institutions

Publication Details

Journal
Astronomy and Astrophysics
Published
2026-01-07
DOI
https://doi.org/10.1051/0004-6361/202555921
Primary Topic
Solar and Space Plasma Dynamics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Superhot (> 30 MK) flare observations with STIX: Joint spectral fitting

Muriel Zoë Stiefel, Säm Krucker, Natália Bajnoková
Astronomy and Astrophysics
Solar and Space Plasma Dynamics
article

Superhot (> 30 MK) flare observations with STIX: Joint spectral fitting

Muriel Zoë Stiefel, Säm Krucker, Natália Bajnoková
article en

Abstract

Context. Spectroscopic analysis of large flares (> X1) in the hard X-ray (HXR) range offers unique insights into the hottest (> 30 MK) flare plasma, the so-called superhot thermal component. To manage the high count rates in large flares, an attenuator is typically placed in front of the HXR detectors. However, this significantly limits the spectral diagnostic capabilities at lower energies, and consequently, it restricts the analysis of the lower temperatures in flares. Aims. The Spectrometer/Telescope for Imaging X-rays (STIX) on board the Solar Orbiter mission was designed to observe solar flares in HXRs. The imaging detectors use an attenuator during periods of high flux. In contrast, the background (BKG) detector of STIX is never covered by the attenuator and is therefore dedicated to measuring the unattenuated flux using differently sized apertures placed in front of the detector. We aim to demonstrate that joint spectral fitting using different detector configurations of STIX allows us to reliably diagnose both the hot and the superhot components in large flares. Methods. We jointly fit the HXR spectra of the STIX BKG detector and the STIX imaging detectors using the SUNKIT-SPEX software package to determine the spectral parameters of both the hot and superhot thermal components in solar flares. Results. Using joint fitting on 32 STIX flares, we corroborated that for GOES X-class flares the HXR spectrum is better represented by two thermal components instead of an isothermal component. At the temperature peak time, the superhot HXR flux above ∼15 keV is typically stronger than the hot HXR flux. The GOES long-wavelength channel is dominated by the hot component with a superhot contribution up to 10%. Conclusions. This paper demonstrates that joint spectral fitting of the same detector type with different attenuation schemes is a simple and powerful method of monitoring multithermal flare plasma.

Astronomy and AstrophysicsVol. 706
FHNW University of Applied Sciences and Arts Northwestern Switzerland (CH), ETH Zurich (CH), Institute of Particle Physics (CA), University of Glasgow (GB)
National Aeronautics and Space Administration, Science and Technology Facilities Council
Openalex Percentile: Top 99%
Solar and Space Plasma Dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.