Comparison of biomechanical behavior between flat head screw and tapered head screw in internal-hex implant-abutment connection

This investigation aimed to evaluate the screw head configuration on its biomechanical performance. Forty-eight screws specimens with four different screw head conical surface opening angle (β) were divided in four groups (n = 12): flat screw head (FHS) with β = 0°, and tapered screw head (THS) with β = 20°, 30°, and 40°. A preload torque of 35 N·cm was applied to fasten the implant-abutment assembly. The initial removal torque values (RTVs) of half the samples in each group were measured. The remaining specimens were then subjected to fatigue tests and the postload RTVs were measured. Furthermore, four 3D prosthesis models were established for FE analysis. The results suggested that the initial and postload RTVs of FHS groups were significantly lower than THS groups (P < .05). After mechanical cycling, the original regular raised texture features on screw head surface in FHS group were almost removed and transferred, while linear grooves appeared near the bottom of the screw head cone in THS group. The FEA results indicated that the highest stress magnitude and maximum torsion angle of the screws occurred in the FHS group. In contrast, the flat-head screw exhibited larger torque loss, greater stress concentration and more severe friction and wear.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-11-13
DOI
https://doi.org/10.1038/s41598-025-23575-x
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of biomechanical behavior between flat head screw and tapered head screw in internal-hex implant-abutment connection

Xianshuai Chen, Zikang Tang, Yuyan Pan, Xiao Zhang et al.
Scientific Reports
Dental Implant Techniques and Outcomes
article

Comparison of biomechanical behavior between flat head screw and tapered head screw in internal-hex implant-abutment connection

Xianshuai Chen, Zikang Tang, Yuyan Pan, Xiao Zhang, Jianyu Chen, Jinyang Zhang
article en

Abstract

This investigation aimed to evaluate the screw head configuration on its biomechanical performance. Forty-eight screws specimens with four different screw head conical surface opening angle (β) were divided in four groups (n = 12): flat screw head (FHS) with β = 0°, and tapered screw head (THS) with β = 20°, 30°, and 40°. A preload torque of 35 N·cm was applied to fasten the implant-abutment assembly. The initial removal torque values (RTVs) of half the samples in each group were measured. The remaining specimens were then subjected to fatigue tests and the postload RTVs were measured. Furthermore, four 3D prosthesis models were established for FE analysis. The results suggested that the initial and postload RTVs of FHS groups were significantly lower than THS groups (P < .05). After mechanical cycling, the original regular raised texture features on screw head surface in FHS group were almost removed and transferred, while linear grooves appeared near the bottom of the screw head cone in THS group. The FEA results indicated that the highest stress magnitude and maximum torsion angle of the screws occurred in the FHS group. In contrast, the flat-head screw exhibited larger torque loss, greater stress concentration and more severe friction and wear.

Scientific ReportsVol. 15(1)
Beike Biotechnology (China) (CN), Stomatology Hospital (CN)
Openalex Percentile: Top 51%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparison of biomechanical behavior between flat head screw and tapered head screw in internal-hex implant-abutment connection — Xianshuai Chen, Zikang Tang, et al. · Scientific Reports (2025) | TGRS Research Map | TGRS