A novel approach for enzyme-based glucose detection: The application of non-faradaic electron impedance spectroscopy for PEDOT-PSS/TiO2 nanocomposite
This study presents a groundbreaking approach to enzyme-based glucose detection through the innovative application of non-faradaic electron impedance spectroscopy (nf-EIS). A precise in situ chemical oxidative method is used for successfully synthesizing Poly(3,4-ethylenedioxythiophene)-Poly(Sodium 4-styrenesulfonate) / Titanium dioxide (PEDOT-PSS / TiO 2 ) nanocomposites. Also fabricated them on Whatman Grade-1 (WG-1) filter paper using the Screen-Printed Electrode method. The structural behaviour and characteristics of the synthesized PEDOT-PSS polymer matrix have been by using advanced techniques, including Fourier transform infrared (FTIR) spectroscopy, X-ray diffraction (XRD), scanning electron microscopy (SEM), ultraviolet-visible (UV-Vis) spectroscopy and Energy Dispersive X-ray Spectroscopy (EDAX) at room temperature (303 K). The analysis of nf-EIS behavior of the fabricated biosensors across varying glucose concentrations demonstrated remarkable insights through impedimetric AC conductivity measurements at a constant voltage (0.3 V). The XRD spectra confirm the presence of the anatase plane in the tetragonal structure of TiO 2 nanoparticles. The average crystallite size and microstrain for all the samples were determined by using the Williamson-Hall (W-H) plot and Debye-Scherrer’s formula. Specifically, sample 15 wt% TiO 2 composite with PEDOT-PSS, among other samples, displayed exceptional sensitivity (9.04 × 10 -7 Sm -1 mM -1 , RSD 1.55%) with a low detection limit (25.84 μM), a rapid response time of just 20 s, following a linear range of 0-40 mM. • With the increasing prevalence of diabetes, this research shows the critical role of improved glucose biosensing technologies in monitoring glucose levels and preventing related health complications after post diseases symptoms. • The innovative enzymatic non-faradaic electron impedance spectroscopy (EIS) tool were used which enhances the accuracy and sensitivity of biosensor. • This study explore the variation of different concentration glucose oxidase (GOx) and the different analytical interference study. • Synergistic effect of PEDOT-PSS/TiO 2 shows the prominent results towards glucose biosensing and also confirmed from it’s characteristics.
Authors
- Deepankar Deshmukh
- Akshaya Pisal Deshmukh (ORCID: https://orcid.org/0009-0006-4272-5837)
- S. P. Yawale (ORCID: https://orcid.org/0000-0001-7176-5180)
- Amritanjali Tiwari (ORCID: https://orcid.org/0000-0001-5547-3903)
- D.S. Yawale
- S. P. Tiwari
- M.S. Dixit
Institutions
- Kanya Maha Vidyalaya (IN)
- G.S. Science, Arts And Commerce College (IN)
- Government Vidarbha Institute of Science and Humanities (IN)
- GLA University (IN)
Publication Details
- Journal
- Biosensors and Bioelectronics X
- Published
- 2025-11-15
- DOI
- https://doi.org/10.1016/j.biosx.2025.100712
- Primary Topic
- Electrochemical sensors and biosensors
- Type
- article
- Field-Weighted Citation Impact
- 0.00