Combined and cross-modal effects of acoustic and indoor air quality conditions on sensory and cognitive responses of university students

• The combined and cross-modal effects of acoustics and IAQ on students were examined. • Combined effects of the stressors were found on response time in a calculation task. • The antagonistic combined effect might be explained through arousal theory. • Environmental stressors affected only the perception of the corresponding domain. • No cross-modal effects were found on soundscape and IAQ assessments. Indoor Environmental Quality (IEQ) plays a crucial role in occupant well-being, particularly in educational settings where suboptimal IEQ impacts students’ cognitive abilities and ultimately their quality of learning. Although research into IEQ in educational settings has increased recently, studies that concurrently examine indoor air quality (IAQ) and acoustic domains remain scarce. This study adopted a multi-domain approach by investigating the combined effects of these two domains on university students’ cognitive abilities, as well as their cross-modal impacts on soundscape and IAQ assessments. In laboratory conditions, 29 students were exposed to two ventilation regimes which led to two bio-effluent levels represented by two CO₂ concentrations (800 and 3000 ppm), and four auditory conditions representative of both mechanical and natural ventilation conditions (Quiet, Babble noise, Mechanical Ventilation noise, and Birdsongs) while performing a calculation task and completing assessments soundscape and IAQ perception. The results revealed a combined effect of IAQ and acoustics on calculation performance, with response times slowing down in quiet as bio-effluents increased. Moreover, only for a high bio-effluent level, response time was faster in Babble noise compared to Quiet or Birdsongs. We speculated that these effects could be explained by the arousal theory. No cross-modal effects of the two domains were found for assessments, while changes in one domain influenced the corresponding perceptual evaluation. Overall, cognitive performance seems to be mediated by an increase in sound-induced arousal, consistent with the Yerkes-Dodson law, with the arousal-performance curve further modulated by IAQ levels.

Authors

Institutions

Publication Details

Journal
Building and Environment
Published
2025-11-15
DOI
https://doi.org/10.1016/j.buildenv.2025.114005
Primary Topic
Noise Effects and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Combined and cross-modal effects of acoustic and indoor air quality conditions on sensory and cognitive responses of university students

Simone Torresin, Chiara Visentin, Nicola Prodi, Francesco Babich et al.
Building and Environment
Noise Effects and Management
article

Combined and cross-modal effects of acoustic and indoor air quality conditions on sensory and cognitive responses of university students

Simone Torresin, Chiara Visentin, Nicola Prodi, Francesco Babich, Pawel Wargocki, Matteo Pellegatti
article en

Abstract

• The combined and cross-modal effects of acoustics and IAQ on students were examined. • Combined effects of the stressors were found on response time in a calculation task. • The antagonistic combined effect might be explained through arousal theory. • Environmental stressors affected only the perception of the corresponding domain. • No cross-modal effects were found on soundscape and IAQ assessments. Indoor Environmental Quality (IEQ) plays a crucial role in occupant well-being, particularly in educational settings where suboptimal IEQ impacts students’ cognitive abilities and ultimately their quality of learning. Although research into IEQ in educational settings has increased recently, studies that concurrently examine indoor air quality (IAQ) and acoustic domains remain scarce. This study adopted a multi-domain approach by investigating the combined effects of these two domains on university students’ cognitive abilities, as well as their cross-modal impacts on soundscape and IAQ assessments. In laboratory conditions, 29 students were exposed to two ventilation regimes which led to two bio-effluent levels represented by two CO₂ concentrations (800 and 3000 ppm), and four auditory conditions representative of both mechanical and natural ventilation conditions (Quiet, Babble noise, Mechanical Ventilation noise, and Birdsongs) while performing a calculation task and completing assessments soundscape and IAQ perception. The results revealed a combined effect of IAQ and acoustics on calculation performance, with response times slowing down in quiet as bio-effluents increased. Moreover, only for a high bio-effluent level, response time was faster in Babble noise compared to Quiet or Birdsongs. We speculated that these effects could be explained by the arousal theory. No cross-modal effects of the two domains were found for assessments, while changes in one domain influenced the corresponding perceptual evaluation. Overall, cognitive performance seems to be mediated by an increase in sound-induced arousal, consistent with the Yerkes-Dodson law, with the arousal-performance curve further modulated by IAQ levels.

Building and EnvironmentVol. 288
Eurac Research (IT), University of Trento (IT), University of Ferrara (IT), Technical University of Denmark (DK)
Openalex Percentile: Top 55%
Noise Effects and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.