An Enhanced Grid-Forming Control Strategy for Suppressing Magnetizing Inrush Current During Black Start of Wind-Storage Systems

Grid-forming wind-storage systems can serve as black-start power sources capable of autonomously establishing voltage and frequency references when the external grid is unavailable, thereby providing crucial support for rapid grid restoration. However, during the black-start process, energizing unloaded transformers often induces severe magnetizing inrush currents, which may cause transient overcurrent, damage grid-forming converters, and compromise system stability. To address this issue, this paper proposes a segmented zero-voltage start strategy and a dual-side converter multi-mode switching control scheme based on small-capacity distributed energy storage. First, the formation mechanism of transformer magnetizing inrush under no-load energization is analyzed. A segmented zero-voltage start module is embedded into the outer voltage loop of the virtual synchronous generator (VSG) controller to enable a smooth rise in output voltage, effectively mitigating transient impacts caused by magnetic core saturation. Second, considering the operating requirements during self-start and load restoration stages, a coordinated control framework for dual-side converters is designed to achieve dynamic voltage, frequency, and power regulation with limited energy storage capacity, thereby improving transient stability and energy utilization efficiency. Finally, real-time hardware-in-the-loop (HIL) simulations conducted on an RT-LAB platform verify the feasibility of the proposed control strategy. The results demonstrate that the method can significantly suppress magnetizing inrush current, transient overvoltage, and overcurrent, thus enhancing the success rate and dynamic stability of black-start operations in grid-forming wind-storage systems.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2025-11-13
DOI
https://doi.org/10.3390/electronics14224431
Citations
1
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
1.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Enhanced Grid-Forming Control Strategy for Suppressing Magnetizing Inrush Current During Black Start of Wind-Storage Systems

Xin Cao, Yifeng Ding, Yi Wan, Jianhui Meng et al.
1 citations
Electronics
Microgrid Control and Optimization
1.21
article

An Enhanced Grid-Forming Control Strategy for Suppressing Magnetizing Inrush Current During Black Start of Wind-Storage Systems

Xin Cao, Yifeng Ding, Yi Wan, Jianhui Meng, Tieheng Zhang, Yucheng Hou, D.-G. Cai
article en
1 citations

Abstract

Grid-forming wind-storage systems can serve as black-start power sources capable of autonomously establishing voltage and frequency references when the external grid is unavailable, thereby providing crucial support for rapid grid restoration. However, during the black-start process, energizing unloaded transformers often induces severe magnetizing inrush currents, which may cause transient overcurrent, damage grid-forming converters, and compromise system stability. To address this issue, this paper proposes a segmented zero-voltage start strategy and a dual-side converter multi-mode switching control scheme based on small-capacity distributed energy storage. First, the formation mechanism of transformer magnetizing inrush under no-load energization is analyzed. A segmented zero-voltage start module is embedded into the outer voltage loop of the virtual synchronous generator (VSG) controller to enable a smooth rise in output voltage, effectively mitigating transient impacts caused by magnetic core saturation. Second, considering the operating requirements during self-start and load restoration stages, a coordinated control framework for dual-side converters is designed to achieve dynamic voltage, frequency, and power regulation with limited energy storage capacity, thereby improving transient stability and energy utilization efficiency. Finally, real-time hardware-in-the-loop (HIL) simulations conducted on an RT-LAB platform verify the feasibility of the proposed control strategy. The results demonstrate that the method can significantly suppress magnetizing inrush current, transient overvoltage, and overcurrent, thus enhancing the success rate and dynamic stability of black-start operations in grid-forming wind-storage systems.

ElectronicsVol. 14(22)
North China Electric Power University (CN), State Grid Corporation of China (China) (CN)
Openalex Percentile: Top 15%
Microgrid Control and Optimization
1.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.