Balancing Discrete Indoor Air Quality Metrics: A Chemical Modeling Study of the Response of Indoor Air Quality to Airborne Pathogen Control Strategies

The impact of airborne pathogen mitigation strategies on indoor air quality (IAQ) depends on the concentration of outdoor air pollutants, the emission and generation of indoor pollutants, and baseline ventilation conditions. Typical engineering solutions to reduce airborne pathogens include enhanced ventilation, in-room filtration, and germicidal ultraviolet (GUV) radiation. Predicting the response of IAQ to these reduction strategies is challenging due to the wide variability in outdoor and indoor air pollutants and numerous configurations for engineered solutions. We use an existing, observationally constrained, open-access photochemical model to assess the response of IAQ metrics to actionable risk reduction strategies in mechanically ventilated buildings. We confirm two commonly held priors: (1) in-room filtration universally reduces PM2.5, while enhancing ventilation rates can increase PM2.5 depending on the quality of the HVAC intake filter and the concentration of outdoor aerosol and (2) enhanced ventilation is the only strategy that reduces the indoor concentration of CO2 and indoor-sourced volatile organic compounds (VOC), but often at the expense of increasing O3 and PM2.5. Uniquely, the model predicts the balance of O3, and aerosol production is driven by the infiltration of outdoor air and photochemically driven indoor air chemistry, where chemical processes are less intuitive. We show that the response of commonly measured proxies for IAQ (e.g., CO2) does not always coincide with an overall improvement in indoor air quality.

Authors

Institutions

Publication Details

Journal
ACS ES&T Air
Published
2025-11-14
DOI
https://doi.org/10.1021/acsestair.5c00211
Citations
1
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
1.20
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Balancing Discrete Indoor Air Quality Metrics: A Chemical Modeling Study of the Response of Indoor Air Quality to Airborne Pathogen Control Strategies

Kevin A. Wokosin, Jon Douglas, Martina N. Rogers, Timothy H. Bertram et al.
1 citations
ACS ES&T Air
Indoor Air Quality and Microbial Exposure
1.20
article

Balancing Discrete Indoor Air Quality Metrics: A Chemical Modeling Study of the Response of Indoor Air Quality to Airborne Pathogen Control Strategies

Kevin A. Wokosin, Jon Douglas, Martina N. Rogers, Timothy H. Bertram, Subi Thakali
article en
1 citations

Abstract

The impact of airborne pathogen mitigation strategies on indoor air quality (IAQ) depends on the concentration of outdoor air pollutants, the emission and generation of indoor pollutants, and baseline ventilation conditions. Typical engineering solutions to reduce airborne pathogens include enhanced ventilation, in-room filtration, and germicidal ultraviolet (GUV) radiation. Predicting the response of IAQ to these reduction strategies is challenging due to the wide variability in outdoor and indoor air pollutants and numerous configurations for engineered solutions. We use an existing, observationally constrained, open-access photochemical model to assess the response of IAQ metrics to actionable risk reduction strategies in mechanically ventilated buildings. We confirm two commonly held priors: (1) in-room filtration universally reduces PM2.5, while enhancing ventilation rates can increase PM2.5 depending on the quality of the HVAC intake filter and the concentration of outdoor aerosol and (2) enhanced ventilation is the only strategy that reduces the indoor concentration of CO2 and indoor-sourced volatile organic compounds (VOC), but often at the expense of increasing O3 and PM2.5. Uniquely, the model predicts the balance of O3, and aerosol production is driven by the infiltration of outdoor air and photochemically driven indoor air chemistry, where chemical processes are less intuitive. We show that the response of commonly measured proxies for IAQ (e.g., CO2) does not always coincide with an overall improvement in indoor air quality.

ACS ES&T AirVol. 2(12)
University of Wisconsin–Madison (US), Johnson Controls (United States) (US)
Openalex Percentile: Top 16%
Indoor Air Quality and Microbial Exposure
1.20
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.