Gait-Induced Myoelectric EEG Artifact Removal Validation from Conventional and Tripolar Concentric Ring Electrodes

(1) Background: Understanding neural dynamics during human movement is a core neuroscience objective, yet there are fundamental challenges to the collection of high-fidelity neuroelectric signals during motion. We investigated the effects of electroencephalography (EEG) electrode design for cleaning high-density EEG, using an electrical testbed that mimicked the human head. (2) Methods: We used a 60-channel high-density array of tripolar concentric ring electrodes and conventional disk electrodes to compare the recovery of simulated brainwave activity in the presence of electrical neck muscle artifacts during walking. Simulated brainwave activity consisted of randomly occurring sinusoidal bursts with unique frequency content within human EEG spectral bands (5–37 Hz). Electrical neck muscle activity was recorded from a human subject during walking and broadcast into the head phantom device at scaled surface recording amplitudes (0× 0.5× 0.67×, 1×, 1.5×, 2×). We compared the number and spatial distribution of detected neural sources among electrode channels based on spectral power. (3) Results: At low muscle activation amplitudes, conventional electrodes identified more spectral power peaks (p ≤ 0.01) among more electrodes (p < 0.05) compared to tripolar concentric ring electrodes, indicating poorer spatial selectivity. At greater muscle artifact amplitudes, conventional electrodes identified fewer neural spectral power peaks (p < 0.05) with lesser localization accuracy (p < 0.05) compared to tripolar concentric ring electrodes. (4) Conclusions: We identified improved myoelectric artifact removal from tripolar concentric ring electrode recordings compared to conventional electrodes, offering a promising approach for recovering high-fidelity electrocortical activity from human subjects during locomotion.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-11-14
DOI
https://doi.org/10.3390/app152212103
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Gait-Induced Myoelectric EEG Artifact Removal Validation from Conventional and Tripolar Concentric Ring Electrodes

Andrew D. Nordin, S.D Phillips
Applied Sciences
EEG and Brain-Computer Interfaces
article

Gait-Induced Myoelectric EEG Artifact Removal Validation from Conventional and Tripolar Concentric Ring Electrodes

Andrew D. Nordin, S.D Phillips
article en

Abstract

(1) Background: Understanding neural dynamics during human movement is a core neuroscience objective, yet there are fundamental challenges to the collection of high-fidelity neuroelectric signals during motion. We investigated the effects of electroencephalography (EEG) electrode design for cleaning high-density EEG, using an electrical testbed that mimicked the human head. (2) Methods: We used a 60-channel high-density array of tripolar concentric ring electrodes and conventional disk electrodes to compare the recovery of simulated brainwave activity in the presence of electrical neck muscle artifacts during walking. Simulated brainwave activity consisted of randomly occurring sinusoidal bursts with unique frequency content within human EEG spectral bands (5–37 Hz). Electrical neck muscle activity was recorded from a human subject during walking and broadcast into the head phantom device at scaled surface recording amplitudes (0× 0.5× 0.67×, 1×, 1.5×, 2×). We compared the number and spatial distribution of detected neural sources among electrode channels based on spectral power. (3) Results: At low muscle activation amplitudes, conventional electrodes identified more spectral power peaks (p ≤ 0.01) among more electrodes (p < 0.05) compared to tripolar concentric ring electrodes, indicating poorer spatial selectivity. At greater muscle artifact amplitudes, conventional electrodes identified fewer neural spectral power peaks (p < 0.05) with lesser localization accuracy (p < 0.05) compared to tripolar concentric ring electrodes. (4) Conclusions: We identified improved myoelectric artifact removal from tripolar concentric ring electrode recordings compared to conventional electrodes, offering a promising approach for recovering high-fidelity electrocortical activity from human subjects during locomotion.

Applied SciencesVol. 15(22)
University of Houston (US), Texas A&M University (US)
Openalex Percentile: Top 66%
EEG and Brain-Computer Interfaces
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.