Airway Proficiency and Efficiency Amongst Anesthesia Providers and Respiratory Therapists: A Comparison Study

<b>Background/Objectives</b>: Studies have demonstrated significant morbidity and mortality associated with airway management, especially when provided outside of the operative setting. The goal of this study was to compare baseline measurements of airway management procedures between anesthesia providers (CRNAs and anesthesiologists) and respiratory therapists using high-fidelity manikins. <b>Methods</b>: This prospective study assessed anesthesia providers and respiratory therapists performing direct laryngoscopy (DL), video laryngoscopy (VL), and LMA placement. The same Laerdal SimMan high-fidelity manikin (Laerdal, Stavanger, Norway) was used in all assessments, with the detection of end-tidal "carbon dioxide" serving as evidence of success for each procedure. Each procedure was performed twice, once under "Healthy Patient" SimMan settings, and once under the "Limited Cervical Range of Motion (ROM)" (DL), "Pharyngeal Obstruction" (VL), and "Full Tongue Edema" (LMA) settings, respectively, to simulate a moderately difficult airway. The order in which the techniques were performed was randomized for each participant. Completion time and number of attempts were recorded for each procedure and compared between the groups. <b>Results</b>: Sixty-two providers (30 anesthesia providers and 32 respiratory therapists) were enrolled. There were no significant differences in average time to completion for any procedure, except respiratory therapists took longer than anesthesia providers in VL with simulated pharyngeal obstruction (<i>p</i> = 0.0004). There were no differences in number of attempts needed for successful completion. <b>Conclusions</b>: This study demonstrates that while completion times for DL and LMA placement were similar amongst provider groups, average time to completion of VL for respiratory therapists was longer under difficult simulated settings. These results reflect potential areas of improvement for other provider groups that may have airway privileges at their respective institutions.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-11-13
DOI
https://doi.org/10.3390/jcm14228059
Primary Topic
Airway Management and Intubation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Airway Proficiency and Efficiency Amongst Anesthesia Providers and Respiratory Therapists: A Comparison Study

Calleigh Brignull, Harper Sprouse, John Sykes, Robert Morgan et al.
Journal of Clinical Medicine
Airway Management and Intubation Techniques
article

Airway Proficiency and Efficiency Amongst Anesthesia Providers and Respiratory Therapists: A Comparison Study

Calleigh Brignull, Harper Sprouse, John Sykes, Robert Morgan, William R. Hand, Stephanie L. Tanner, Kyle J. Adams, E. Williams, Henry Moulder
article en

Abstract

<b>Background/Objectives</b>: Studies have demonstrated significant morbidity and mortality associated with airway management, especially when provided outside of the operative setting. The goal of this study was to compare baseline measurements of airway management procedures between anesthesia providers (CRNAs and anesthesiologists) and respiratory therapists using high-fidelity manikins. <b>Methods</b>: This prospective study assessed anesthesia providers and respiratory therapists performing direct laryngoscopy (DL), video laryngoscopy (VL), and LMA placement. The same Laerdal SimMan high-fidelity manikin (Laerdal, Stavanger, Norway) was used in all assessments, with the detection of end-tidal "carbon dioxide" serving as evidence of success for each procedure. Each procedure was performed twice, once under "Healthy Patient" SimMan settings, and once under the "Limited Cervical Range of Motion (ROM)" (DL), "Pharyngeal Obstruction" (VL), and "Full Tongue Edema" (LMA) settings, respectively, to simulate a moderately difficult airway. The order in which the techniques were performed was randomized for each participant. Completion time and number of attempts were recorded for each procedure and compared between the groups. <b>Results</b>: Sixty-two providers (30 anesthesia providers and 32 respiratory therapists) were enrolled. There were no significant differences in average time to completion for any procedure, except respiratory therapists took longer than anesthesia providers in VL with simulated pharyngeal obstruction (<i>p</i> = 0.0004). There were no differences in number of attempts needed for successful completion. <b>Conclusions</b>: This study demonstrates that while completion times for DL and LMA placement were similar amongst provider groups, average time to completion of VL for respiratory therapists was longer under difficult simulated settings. These results reflect potential areas of improvement for other provider groups that may have airway privileges at their respective institutions.

Journal of Clinical MedicineVol. 14(22)
Prisma Health (US)
Openalex Percentile: Top 48%
Airway Management and Intubation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.