Dual Foreign Body Response Mitigation Strategies for Implantable Glucose Sensors

While nitric oxide (NO) release from polyurethane (PU) sensor membranes has shown promise as a foreign body response (FBR) mitigation strategy to enhance the performance of implantable glucose sensors, its utility is ultimately limited by release duration. Further improvement is envisioned by combining electrospun fibers with NO release. Electrospinning process parameters that produce average fiber diameters of 670 and 1460 nm as the outer membrane of NO‐releasing glucose sensors, are developed to not impact NO‐release or sensor performance. An in vivo evaluation in a diabetic porcine model demonstrates a reduced inflammatory response for 670 versus 1460 nm fibers. This benefit appears to continue with a robust pro‐wound healing response beyond the NO‐release duration. At short periods (i.e., 11‐d post‐implantation), FBR mitigation is attributed to NO release and not the presence of fibers. Still, no negative effects are observed with the 670 nm fibers in this acute phase of the FBR. Taken together, the tissue response data demonstrate 670 nm fibers as a promising long‐term FBR mitigation strategy.

Authors

Institutions

Publication Details

Journal
UNC Libraries
Published
2025-08-07
DOI
https://doi.org/10.17615/22qz-qf55
Primary Topic
Electrospun Nanofibers in Biomedical Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dual Foreign Body Response Mitigation Strategies for Implantable Glucose Sensors

Robert Maile, Micah L. Willis, Mark H. Schoenfisch, Elizabeth P. Merricks et al.
UNC Libraries
Electrospun Nanofibers in Biomedical Applications
article

Dual Foreign Body Response Mitigation Strategies for Implantable Glucose Sensors

Robert Maile, Micah L. Willis, Mark H. Schoenfisch, Elizabeth P. Merricks, Shannon Margaret Wallet, Timothy C. Nichols, Alejandro R. Walker, Taron M. Bradshaw, Mikaylin E. Nogler, Matthew F. Warchol
article en

Abstract

While nitric oxide (NO) release from polyurethane (PU) sensor membranes has shown promise as a foreign body response (FBR) mitigation strategy to enhance the performance of implantable glucose sensors, its utility is ultimately limited by release duration. Further improvement is envisioned by combining electrospun fibers with NO release. Electrospinning process parameters that produce average fiber diameters of 670 and 1460 nm as the outer membrane of NO‐releasing glucose sensors, are developed to not impact NO‐release or sensor performance. An in vivo evaluation in a diabetic porcine model demonstrates a reduced inflammatory response for 670 versus 1460 nm fibers. This benefit appears to continue with a robust pro‐wound healing response beyond the NO‐release duration. At short periods (i.e., 11‐d post‐implantation), FBR mitigation is attributed to NO release and not the presence of fibers. Still, no negative effects are observed with the 670 nm fibers in this acute phase of the FBR. Taken together, the tissue response data demonstrate 670 nm fibers as a promising long‐term FBR mitigation strategy.

UNC Libraries
University of North Carolina at Chapel Hill (US)
Openalex Percentile: Top 77%
Electrospun Nanofibers in Biomedical Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Dual Foreign Body Response Mitigation Strategies for Implantable Glucose Sensors — Robert Maile, Micah L. Willis, et al. · UNC Libraries (2025) | TGRS Research Map | TGRS