The value of flow velocity alterations measured by carotid Doppler in the diagnosis of acute anterior ischemic stroke

Abstract Background Acute ischemic stroke is a leading cause of mortality and long‐term disability. Conventional imaging methods like CT and MRI, while essential, are limited by cost, accessibility, and the need for patient transport. Carotid Doppler ultrasonography is a non‐invasive, low‐cost tool that can be performed bedside, yet its utility in detecting hemodynamic changes in acute ischemic stroke—particularly in the absence of structural stenosis—requires further evaluation. Methods This prospective case‐control study included 64 acute anterior ischemic stroke (AAIS) patients and 64 healthy controls. Using bedside carotid Doppler ultrasound, bilateral measurements of velocity time integral (VTI), peak systolic velocity (PSV), and arterial diameter were obtained. VTI and PSV indices were calculated as the percentage difference between right and left sides. Diagnostic accuracy was assessed through receiver operating characteristic (ROC) analysis and logistic regression. Results The AAIS group showed significantly higher VTI and PSV indices compared to controls ( p < 0.001). ROC analysis demonstrated good diagnostic performance (area under curve: 0.789 for VTI and 0.865 for PSV). At optimal cut‐off values (VTI > 5.1%; PSV > 6.35%), sensitivity and specificity exceeded 73% for both. Logistic regression identified both indices as independent predictors of AAIS (OR: 6.948 for VTI, OR: 13.461 for PSV), and the combined model explained 53.7% of stroke likelihood (Nagelkerke R 2 = 0.537). Conclusion VTI and PSV indices measured by carotid Doppler ultrasound are effective, noninvasive diagnostic tools for AAIS. Their bedside applicability makes them especially valuable in emergency settings where rapid decision‐making is crucial.

Authors

Institutions

Publication Details

Journal
Hong Kong Journal of Emergency Medicine
Published
2025-11-14
DOI
https://doi.org/10.1002/hkj2.12081
Primary Topic
Acute Ischemic Stroke Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The value of flow velocity alterations measured by carotid Doppler in the diagnosis of acute anterior ischemic stroke

Ejder Saylav Bora, Zeynep Karakaya, Adnan Yamanoğlu, Hüseyin Acar et al.
Hong Kong Journal of Emergency Medicine
Acute Ischemic Stroke Management
article

The value of flow velocity alterations measured by carotid Doppler in the diagnosis of acute anterior ischemic stroke

Ejder Saylav Bora, Zeynep Karakaya, Adnan Yamanoğlu, Hüseyin Acar, Melih Şengün
article en

Abstract

Abstract Background Acute ischemic stroke is a leading cause of mortality and long‐term disability. Conventional imaging methods like CT and MRI, while essential, are limited by cost, accessibility, and the need for patient transport. Carotid Doppler ultrasonography is a non‐invasive, low‐cost tool that can be performed bedside, yet its utility in detecting hemodynamic changes in acute ischemic stroke—particularly in the absence of structural stenosis—requires further evaluation. Methods This prospective case‐control study included 64 acute anterior ischemic stroke (AAIS) patients and 64 healthy controls. Using bedside carotid Doppler ultrasound, bilateral measurements of velocity time integral (VTI), peak systolic velocity (PSV), and arterial diameter were obtained. VTI and PSV indices were calculated as the percentage difference between right and left sides. Diagnostic accuracy was assessed through receiver operating characteristic (ROC) analysis and logistic regression. Results The AAIS group showed significantly higher VTI and PSV indices compared to controls ( p < 0.001). ROC analysis demonstrated good diagnostic performance (area under curve: 0.789 for VTI and 0.865 for PSV). At optimal cut‐off values (VTI > 5.1%; PSV > 6.35%), sensitivity and specificity exceeded 73% for both. Logistic regression identified both indices as independent predictors of AAIS (OR: 6.948 for VTI, OR: 13.461 for PSV), and the combined model explained 53.7% of stroke likelihood (Nagelkerke R 2 = 0.537). Conclusion VTI and PSV indices measured by carotid Doppler ultrasound are effective, noninvasive diagnostic tools for AAIS. Their bedside applicability makes them especially valuable in emergency settings where rapid decision‐making is crucial.

Hong Kong Journal of Emergency MedicineVol. 32(6)
Izmir Kâtip Çelebi University (TR)
Openalex Percentile: Top 55%
Acute Ischemic Stroke Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.