Synergetic Allocation and Operation of Hybrid Energy Storage System and Unified Power Quality Conditioner for Power Quality Enhancement of Distribution Networks with Renewables

With the penetration of renewable power generation (RPG) in the distribution network (DN), power quality issues caused by RPG fluctuations have become more prominent than ever, let alone the integration of new types of power loads like electrified trains and electric vehicles that are major harmonic sources. Traditional power quality enhancement approaches are mostly dedicated to the smoothing of RPG power output or active compensation of harmonics, but fail to incorporate both routines into one single power quality enhancement scheme. Out of this research motivation, this paper aims to propose a synergetic allocation scheme for the hybrid energy storage system (HESS) and the unified power quality conditioner (UPQC) to achieve superior power quality enhancement. Firstly, a novel comprehensive vulnerability index of the DN suited for the power quality issues is presented to reflect the key factors that may impact the bus voltage security. Afterwards, the capacity specifications of HESS and UPQC for power smoothing and load side harmonic compensation are deduced with variational mode decomposition and inverter capacity configurations. Subsequently, the synergetic allocation method of HESS and UPQC are proposed by formulating an optimization problem, with the former obtained capacity specifications acting as the main constraints. After that, a dynamic hourly network reconfiguration approach is proposed to enhance the vulnerability level of the DN by dynamically changing its topology, and ensuring better power quality with the optimally allocated HESS and UPQC. Finally, simulation tests and comparative studies are conducted to evaluate the effectiveness and performance of the proposed scheme by comparing with existing methods. The comparative study has shown that the proposed method can reduce bus voltage deviation by 2.63%; meanwhile, it can reduce the total harmonic distortion by 1.83%.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2025-11-14
DOI
https://doi.org/10.3390/electronics14224455
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Synergetic Allocation and Operation of Hybrid Energy Storage System and Unified Power Quality Conditioner for Power Quality Enhancement of Distribution Networks with Renewables

Peng Zhuang, Sheng-Wei Guan, Yu Niu, Li Zhou et al.
Electronics
Power Quality and Harmonics
article

Synergetic Allocation and Operation of Hybrid Energy Storage System and Unified Power Quality Conditioner for Power Quality Enhancement of Distribution Networks with Renewables

Peng Zhuang, Sheng-Wei Guan, Yu Niu, Li Zhou, Fujun Bao, Yanbing Li
article en

Abstract

With the penetration of renewable power generation (RPG) in the distribution network (DN), power quality issues caused by RPG fluctuations have become more prominent than ever, let alone the integration of new types of power loads like electrified trains and electric vehicles that are major harmonic sources. Traditional power quality enhancement approaches are mostly dedicated to the smoothing of RPG power output or active compensation of harmonics, but fail to incorporate both routines into one single power quality enhancement scheme. Out of this research motivation, this paper aims to propose a synergetic allocation scheme for the hybrid energy storage system (HESS) and the unified power quality conditioner (UPQC) to achieve superior power quality enhancement. Firstly, a novel comprehensive vulnerability index of the DN suited for the power quality issues is presented to reflect the key factors that may impact the bus voltage security. Afterwards, the capacity specifications of HESS and UPQC for power smoothing and load side harmonic compensation are deduced with variational mode decomposition and inverter capacity configurations. Subsequently, the synergetic allocation method of HESS and UPQC are proposed by formulating an optimization problem, with the former obtained capacity specifications acting as the main constraints. After that, a dynamic hourly network reconfiguration approach is proposed to enhance the vulnerability level of the DN by dynamically changing its topology, and ensuring better power quality with the optimally allocated HESS and UPQC. Finally, simulation tests and comparative studies are conducted to evaluate the effectiveness and performance of the proposed scheme by comparing with existing methods. The comparative study has shown that the proposed method can reduce bus voltage deviation by 2.63%; meanwhile, it can reduce the total harmonic distortion by 1.83%.

ElectronicsVol. 14(22)
Zhengzhou University (CN), Henan Energy & Chemical Industry Group (China) (CN)
State Grid Henan Electric Power Company
Openalex Percentile: Top 66%
Power Quality and Harmonics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.