Numerical study of the behaviour of hollow unreinforced concrete masonry subject to eccentric axial load and examination of North American design standard provisions

Inaccuracies and inconsistencies in international design standard predictions of eccentrically loaded slender concrete masonry wall (SCMW) behaviour have long been noted. Scarce experimental data has limited the development of accurate provisions. As SCMW experimental work is complex, a numerical model presents value as a rational guide for future experiments and to compare against current SCMW design provisions. In this study, a three-dimensional detailed micro-model is developed for HSCMWs. The model is validated against recent HSCMW experimental strength and stiffness data. Different uniaxial compression stress-strain curves and initial imperfections are considered. Assumed compressive stress-strain behaviour is found to especially influence numerical HSCMW flexural stiffness; initial imperfections are found to reduce wall axial capacity up to 15 % among considered cases. A preliminary comparison of CSA S304–24 and TMS 402/602–22 HSCMW provisions against each other and the numerical model is then presented. Differences in maximum axial compressive stress ( f c ) between both standards are found to particularly drive differences in predicted strength. By comparing both standards against the numerical results, it is suggested both standards permit linear elastic analysis of cross-sectional stresses without penalty, and that the use of a higher f c in CSA S304–24 be considered. • A 3D detailed micro-model is developed for hollow concrete masonry walls. • Chosen uniaxial stress-strain curve particularly affects numerical flexural stiffness. • Effect of load eccentricity, end fixity, effective height, imperfection presented. • Normalized standard strength values differ from FE by up to 0.71 (CSA), 0.46 (TMS). • Changes to peak axial stress, linear elastic analysis clauses advised for CSA S304.

Authors

Institutions

Publication Details

Journal
Engineering Structures
Published
2025-11-14
DOI
https://doi.org/10.1016/j.engstruct.2025.121745
Primary Topic
Masonry and Concrete Structural Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical study of the behaviour of hollow unreinforced concrete masonry subject to eccentric axial load and examination of North American design standard provisions

George Iskander, Nigel G. Shrive, Ali Ahmed
Engineering Structures
Masonry and Concrete Structural Analysis
article

Numerical study of the behaviour of hollow unreinforced concrete masonry subject to eccentric axial load and examination of North American design standard provisions

George Iskander, Nigel G. Shrive, Ali Ahmed
article en

Abstract

Inaccuracies and inconsistencies in international design standard predictions of eccentrically loaded slender concrete masonry wall (SCMW) behaviour have long been noted. Scarce experimental data has limited the development of accurate provisions. As SCMW experimental work is complex, a numerical model presents value as a rational guide for future experiments and to compare against current SCMW design provisions. In this study, a three-dimensional detailed micro-model is developed for HSCMWs. The model is validated against recent HSCMW experimental strength and stiffness data. Different uniaxial compression stress-strain curves and initial imperfections are considered. Assumed compressive stress-strain behaviour is found to especially influence numerical HSCMW flexural stiffness; initial imperfections are found to reduce wall axial capacity up to 15 % among considered cases. A preliminary comparison of CSA S304–24 and TMS 402/602–22 HSCMW provisions against each other and the numerical model is then presented. Differences in maximum axial compressive stress ( f c ) between both standards are found to particularly drive differences in predicted strength. By comparing both standards against the numerical results, it is suggested both standards permit linear elastic analysis of cross-sectional stresses without penalty, and that the use of a higher f c in CSA S304–24 be considered. • A 3D detailed micro-model is developed for hollow concrete masonry walls. • Chosen uniaxial stress-strain curve particularly affects numerical flexural stiffness. • Effect of load eccentricity, end fixity, effective height, imperfection presented. • Normalized standard strength values differ from FE by up to 0.71 (CSA), 0.46 (TMS). • Changes to peak axial stress, linear elastic analysis clauses advised for CSA S304.

Engineering StructuresVol. 347
University of Calgary (CA)
Openalex Percentile: Top 64%
Masonry and Concrete Structural Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.