PEA Measurement on 525kV HVDC Cable Compliant with IEEE 1732 Recommendation

In 2017, IEEE proposed a procedure to evaluate the effect of space charge accumulation in extruded cables for HVDC applications with rated voltages up to 550kV. In this paper, the results of a measurement performed with the Pulsed Electro-Acoustic (PEA) method are reported, according to the guidelines of the IEEE recommendation. The measurement has been performed on a full-size cable with rated voltage of 525kV. The procedure involves a phase of positive volt-on (U0) and volt-off and another of negative volt-on (-U<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0</inf>) and volt-off. The results show that both in the positive volt-on phase (lasting 9 hours) and in the negative volt-on phase (lasting 6 hours), the electric field profile underwent an inversion process. Having performed a continuous acquisition of the charge profile, it was observed that the inversion occurs in both cases during the first hour. While the stabilization of the field profile occurred first in the negative volt-on phase.

Authors

Institutions

Publication Details

Published
2024-10-06
DOI
https://doi.org/10.1109/ceidp61745.2024.10907616
Citations
1
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.12
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

PEA Measurement on 525kV HVDC Cable Compliant with IEEE 1732 Recommendation

Pietro Romano, Antonino Imburgia, Marco Albertini, Guido Ala et al.
1 citations
High voltage insulation and dielectric phenomena
0.12
article

PEA Measurement on 525kV HVDC Cable Compliant with IEEE 1732 Recommendation

Pietro Romano, Antonino Imburgia, Marco Albertini, Guido Ala, Grazia Berardi, Giuseppe Rizzo, S. Franchi Benoni, R. Candela, Vincenzo Li Vigni, Alessio Di Fatta, Ghulam Akbar
article en
1 citations

Abstract

In 2017, IEEE proposed a procedure to evaluate the effect of space charge accumulation in extruded cables for HVDC applications with rated voltages up to 550kV. In this paper, the results of a measurement performed with the Pulsed Electro-Acoustic (PEA) method are reported, according to the guidelines of the IEEE recommendation. The measurement has been performed on a full-size cable with rated voltage of 525kV. The procedure involves a phase of positive volt-on (U0) and volt-off and another of negative volt-on (-U<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0</inf>) and volt-off. The results show that both in the positive volt-on phase (lasting 9 hours) and in the negative volt-on phase (lasting 6 hours), the electric field profile underwent an inversion process. Having performed a continuous acquisition of the charge profile, it was observed that the inversion occurs in both cases during the first hour. While the stabilization of the field profile occurred first in the negative volt-on phase.

Prysmian Group (Italy) (IT), University of Palermo (IT)
Openalex Percentile: Top 56%
High voltage insulation and dielectric phenomena
0.12
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.