Continuous Wireless Vital Sign Sensors for Detecting Severe Deviations at a Transitional Care Facility—An Observational Feasibility Study

After hospital admissions, patients may be discharged to a transitional care facility if they are considered physically or mentally unable to be at home. This study aimed to assess the feasibility of continuous wearable vital sign monitoring (CVSM) at a low-staffed transitional care facility. This was a feasibility study exploring CVSM (blinded for staff) for up to 96 h in 20 patients discharged to a transitional care facility. Feasibility was assessed by monitoring duration. Secondarily, deviating vital sign values from both CVSM and manual vital sign monitoring were described. Twenty patients were continuously monitored for 1565 h in total. The median duration of monitoring with at least one device was 80 h (IQR 50-93), equivalent to 83% of the monitored period. The median cumulative duration of abnormal vital signs was 620 min [IQR 336 min-930 min]. The transitional care facility staff did not assess vital signs in any patients during the monitored period. Forty percent of patients developed at least one medical complication and were readmitted to the hospital.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-11-14
DOI
https://doi.org/10.3390/s25226970
Primary Topic
Sepsis Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Continuous Wireless Vital Sign Sensors for Detecting Severe Deviations at a Transitional Care Facility—An Observational Feasibility Study

Eske Kvanner Aasvang, Christian Sylvest Meyhoff, L Andersen, Søren M. Rasmussen et al.
Sensors
Sepsis Diagnosis and Treatment
article

Continuous Wireless Vital Sign Sensors for Detecting Severe Deviations at a Transitional Care Facility—An Observational Feasibility Study

Eske Kvanner Aasvang, Christian Sylvest Meyhoff, L Andersen, Søren M. Rasmussen, Jesper Mølgaard, Camilla Haahr‐Raunkjaer
article en

Abstract

After hospital admissions, patients may be discharged to a transitional care facility if they are considered physically or mentally unable to be at home. This study aimed to assess the feasibility of continuous wearable vital sign monitoring (CVSM) at a low-staffed transitional care facility. This was a feasibility study exploring CVSM (blinded for staff) for up to 96 h in 20 patients discharged to a transitional care facility. Feasibility was assessed by monitoring duration. Secondarily, deviating vital sign values from both CVSM and manual vital sign monitoring were described. Twenty patients were continuously monitored for 1565 h in total. The median duration of monitoring with at least one device was 80 h (IQR 50-93), equivalent to 83% of the monitored period. The median cumulative duration of abnormal vital signs was 620 min [IQR 336 min-930 min]. The transitional care facility staff did not assess vital signs in any patients during the monitored period. Forty percent of patients developed at least one medical complication and were readmitted to the hospital.

SensorsVol. 25(22)
University of Copenhagen (DK), Frederiksberg Hospital (DK), Copenhagen University Hospital (DK), Capital Region of Denmark (DK), Technical University of Denmark (DK)
Openalex Percentile: Top 55%
Sepsis Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Continuous Wireless Vital Sign Sensors for Detecting Severe Deviations at a Transitional Care Facility—An Observational Feasibility Study — Eske Kvanner Aasvang, Christian Sylvest Meyhoff, et al. · Sensors (2025) | TGRS Research Map | TGRS