ACETABULAR AUGMENTS USED IN REVISION HIP ARTHROPLASTY: MINIMUM TEN-YEAR FOLLOW-UP OF IMPLANT SURVIVORSHIP, FUNCTIONAL SCORES, AND RADIOLOGICAL OUTCOMES

Addressing acetabular bone loss in the context of hip revision surgeries constitutes a significant challenge in orthopedics. The use of Trabecular Metal (TM) augments emerges as a viable solution, yet there is a lack of comprehensive data detailing their long-term outcomes [1,2]. The purpose of this study was to evaluate the long-term implant survival rates, functional outcomes, and radiographic findings associated with the use of TM augments in hip revision surgery. We conducted a retrospective review of 80 patients who underwent hip revision with TM augments over a 13-year period. Kaplan-Meier analysis was carried out, with functional outcomes assessed using the Harris Hip Score (HHS) and Oxford Hip Score (OHS). Radiographic analysis was conducted to assess incidence of osteolysis. Kaplan-Meier analysis demonstrated impressive survival rates of 96.8% augment survival at 5 years and 92.3% at 10 years. There was a marked improvement in the functional hip scores: mean HHS rose from a pre-operative 39.35, indicative of severe pain and major functional limitations, to a 10-year post-operative 75.75, suggesting milder pain and reduced limitations. Likewise, pre-operative OHS, averaging at 15.09 (severe arthritis), improved to 36.8 (mild arthritis) at 5 years post-operation. The incidence of osteolysis was found to be 33.75% at the final radiographic follow-up. Our study validates the use of TM augments for acetabular bone loss in hip revisions. Regular patient monitoring for osteolysis and prevention of late augment failure is vital. By providing robust long-term data, this study enhances the existing body of literature, thus guiding future surgical decisions.

Authors

Institutions

Publication Details

Journal
Orthopaedic Proceedings
Published
2025-11-14
DOI
https://doi.org/10.1302/1358-992x.2025.13.006
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ACETABULAR AUGMENTS USED IN REVISION HIP ARTHROPLASTY: MINIMUM TEN-YEAR FOLLOW-UP OF IMPLANT SURVIVORSHIP, FUNCTIONAL SCORES, AND RADIOLOGICAL OUTCOMES

Allan E. Gross, Alexander Greenberg, Anser Daud, Paul R.T. Kuzyk et al.
Orthopaedic Proceedings
Orthopaedic implants and arthroplasty
article

ACETABULAR AUGMENTS USED IN REVISION HIP ARTHROPLASTY: MINIMUM TEN-YEAR FOLLOW-UP OF IMPLANT SURVIVORSHIP, FUNCTIONAL SCORES, AND RADIOLOGICAL OUTCOMES

Allan E. Gross, Alexander Greenberg, Anser Daud, Paul R.T. Kuzyk, Oleg Safir, Doris Braunstein, Faran Chaudhry
article en

Abstract

Addressing acetabular bone loss in the context of hip revision surgeries constitutes a significant challenge in orthopedics. The use of Trabecular Metal (TM) augments emerges as a viable solution, yet there is a lack of comprehensive data detailing their long-term outcomes [1,2]. The purpose of this study was to evaluate the long-term implant survival rates, functional outcomes, and radiographic findings associated with the use of TM augments in hip revision surgery. We conducted a retrospective review of 80 patients who underwent hip revision with TM augments over a 13-year period. Kaplan-Meier analysis was carried out, with functional outcomes assessed using the Harris Hip Score (HHS) and Oxford Hip Score (OHS). Radiographic analysis was conducted to assess incidence of osteolysis. Kaplan-Meier analysis demonstrated impressive survival rates of 96.8% augment survival at 5 years and 92.3% at 10 years. There was a marked improvement in the functional hip scores: mean HHS rose from a pre-operative 39.35, indicative of severe pain and major functional limitations, to a 10-year post-operative 75.75, suggesting milder pain and reduced limitations. Likewise, pre-operative OHS, averaging at 15.09 (severe arthritis), improved to 36.8 (mild arthritis) at 5 years post-operation. The incidence of osteolysis was found to be 33.75% at the final radiographic follow-up. Our study validates the use of TM augments for acetabular bone loss in hip revisions. Regular patient monitoring for osteolysis and prevention of late augment failure is vital. By providing robust long-term data, this study enhances the existing body of literature, thus guiding future surgical decisions.

Orthopaedic ProceedingsVol. 107-B(SUPP_13)
University of Toronto (CA)
Openalex Percentile: Top 47%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.