Identifying a digital phenotype of allostatic load: association between allostatic load index score and wearable physiological response during military training

Allostatic load, a maladaptive biological process wherein physiological stability ("allostasis") fails owing to chronic stress exposure, is traditionally measured by the allostatic load index (ALI). Whether ALI is associated with wearable-assessed physiological responses remains unknown. We aimed to determine the association between ALI and wearable-assessed physiological responses during a 10-wk military training course. Twenty-five participants (12 women) with ALI and suitable wearable data [84.31% complete data (range: 64.71%-97.56%)] were included. ALI (0-8) was calculated using biomarker components from neuroendocrine, autonomic, and immune systems. Device variables included total energy expenditure (TEE), energy expenditure during physical activity (PAEE), daytime heart rate (HR), sleeping HR, nonlinear HR variability (detrended fluctuation analysis, DFA-α<sub>1</sub>), and sleep architecture. Flux was calculated as raw (Δ) or absolute difference (|Δ|) in average values between days and nights. Generalized linear mixed effect models assessed the association between high allostatic load (ALI > 4) and responses (α = 0.05). Twelve (4 women) participants experienced ALI > 4. High allostatic load was associated with TEE (β = 0.658, standard error (SE) = 0.002, odds ratio (OR) = 1.931, <i>P</i> < 0.001), Δ in relative PAEE (β = 0.472, SE = 0.002, OR = 1.602, <i>P</i> < 0.001), daytime HR (β = 0.189, SE = 0.002, OR = 1.208, <i>P</i> < 0.001), |Δ| in relative daytime HR (β = 0.262, SE = 0.001, OR = 1.298, <i>P</i> < 0.001), and |Δ| in relative sleeping HR (β = -0.048, SE = 0.001, OR = 0.953, <i>P</i> < 0.001). Every one-standard-deviation increase in absolute TEE, flux in relative PAEE, daytime HR, flux in daytime HR, and reduced flux in sleeping HR increased the risk of high allostatic load by 5%-90%. Chronically elevated and variable cardiometabolic activity with blunted night-to-night variation in sleeping HR may be a digital phenotype of high allostatic load in military personnel.<b>NEW & NOTEWORTHY</b> This investigation for the first time observed an association between the traditional measurement of allostatic load, the allostatic load index, and wearable-assessed physiological responses to strenuous military training stress. We found a novel digital phenotype of allostatic load characterized by chronically elevated and variable cardiometabolic activity with blunted variation in heart rate during sleep. This phenotype may serve as an at-risk profile of high allostatic load and prompt in-training modifications to enhance posttraining readiness.

Authors

Institutions

Publication Details

Journal
American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
Published
2025-11-12
DOI
https://doi.org/10.1152/ajpregu.00216.2025
Citations
1
Primary Topic
Heart Rate Variability and Autonomic Control
Type
article
Field-Weighted Citation Impact
1.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Identifying a digital phenotype of allostatic load: association between allostatic load index score and wearable physiological response during military training

Matthew B. Bird, Kristen J. Koltun, Karl E. Friedl, Brian J. Martin et al.
1 citations
American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
Heart Rate Variability and Autonomic Control
1.39
article

Identifying a digital phenotype of allostatic load: association between allostatic load index score and wearable physiological response during military training

Matthew B. Bird, Kristen J. Koltun, Karl E. Friedl, Brian J. Martin, Tim L. A. Doyle, Jennifer N. Forse, Bradley C. Nindl, Mita Lovalekar, Elizabeth J. Steele, Christopher K. Kargl, Evan D. Feigel, Elizabeth F. Nagle
article en
1 citations

Abstract

Allostatic load, a maladaptive biological process wherein physiological stability ("allostasis") fails owing to chronic stress exposure, is traditionally measured by the allostatic load index (ALI). Whether ALI is associated with wearable-assessed physiological responses remains unknown. We aimed to determine the association between ALI and wearable-assessed physiological responses during a 10-wk military training course. Twenty-five participants (12 women) with ALI and suitable wearable data [84.31% complete data (range: 64.71%-97.56%)] were included. ALI (0-8) was calculated using biomarker components from neuroendocrine, autonomic, and immune systems. Device variables included total energy expenditure (TEE), energy expenditure during physical activity (PAEE), daytime heart rate (HR), sleeping HR, nonlinear HR variability (detrended fluctuation analysis, DFA-α<sub>1</sub>), and sleep architecture. Flux was calculated as raw (Δ) or absolute difference (|Δ|) in average values between days and nights. Generalized linear mixed effect models assessed the association between high allostatic load (ALI > 4) and responses (α = 0.05). Twelve (4 women) participants experienced ALI > 4. High allostatic load was associated with TEE (β = 0.658, standard error (SE) = 0.002, odds ratio (OR) = 1.931, <i>P</i> < 0.001), Δ in relative PAEE (β = 0.472, SE = 0.002, OR = 1.602, <i>P</i> < 0.001), daytime HR (β = 0.189, SE = 0.002, OR = 1.208, <i>P</i> < 0.001), |Δ| in relative daytime HR (β = 0.262, SE = 0.001, OR = 1.298, <i>P</i> < 0.001), and |Δ| in relative sleeping HR (β = -0.048, SE = 0.001, OR = 0.953, <i>P</i> < 0.001). Every one-standard-deviation increase in absolute TEE, flux in relative PAEE, daytime HR, flux in daytime HR, and reduced flux in sleeping HR increased the risk of high allostatic load by 5%-90%. Chronically elevated and variable cardiometabolic activity with blunted night-to-night variation in sleeping HR may be a digital phenotype of high allostatic load in military personnel.<b>NEW & NOTEWORTHY</b> This investigation for the first time observed an association between the traditional measurement of allostatic load, the allostatic load index, and wearable-assessed physiological responses to strenuous military training stress. We found a novel digital phenotype of allostatic load characterized by chronically elevated and variable cardiometabolic activity with blunted variation in heart rate during sleep. This phenotype may serve as an at-risk profile of high allostatic load and prompt in-training modifications to enhance posttraining readiness.

American Journal of Physiology-Regulatory, Integrative and Comparative PhysiologyVol. 329(6)
U.S. Army Research Institute of Environmental Medicine (US), University of Pittsburgh (US), Macquarie University (AU)
Openalex Percentile: Top 13%
Heart Rate Variability and Autonomic Control
1.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.