A robust method for weak node detection for optimal VAr allocation has been proposed in this research. Modal or eigenvalue analysis, loss-sensitivity analysis, power flow analysis, L-index, and fast voltage stability index methods were employed to identify weak nodes in medium and large power networks using IEEE 57 and IEEE 118 bus systems. After identifying the locations for shunt VAr allocation, several standard optimization techniques i.e. Genetic Algorithm, Differential Evolution, Particle Swarm Optimization, Teaching-Learning-Based Optimization, Big Bang-Big Crunch, Krill Herd Algorithm, and Sine-Cosine Algorithm were then applied for optimal reactive power planning. These methods were aimed to coordinate VAr injections by shunt capacitors at weak nodes with existing VAr sources such as generators and On-Load Tap Changers. A comprehensive study of various standard detection techniques and their usefulness in power system planning is presented by the authors. Finally, authors deduced LSI (Line Stability Index) method of weak node detection was the most accurate method for weak node detection. Carrying out the proposed methodology, the total active power loss with GA & DE was found as 0.2348 p.u. & 0.2351 p.u. respectively for IEEE 57 bus test network and total operating cost was found as $1.2344 × 10 7 for GA & $1.2357 × 10 7 for DE. Similarly, for the IEEE 118-bus test network, the active power loss reported under GA and DE was 1.3295 p.u. each, with corresponding operating costs of $6.9885 × 10 7 and $6.9880 × 10 7 , respectively. This research offers a comprehensive framework for reducing operating cost and active power loss in reactive power planning. • Detection of weak nodes of a large power network. • Proposition of optimal VAr adjustments by the OLTC's, generators, and the shunt VAr injection at weak nodes. • Use of different optimization techniques to accomplish the task. • Comparative analysis of different techniques on the basis of the results obtained. • Deduction of loss and cost minimum configuration of the power network.

Authors

Institutions

Publication Details

Journal
Measurement Energy
Published
2025-11-14
DOI
https://doi.org/10.1016/j.meaene.2025.100077
Citations
1
Primary Topic
Optimal Power Flow Distribution
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimal VAr management of a large power network using most efficient method of weak node detection

B. Bhattacharyya, Suraj Kumar Rajbhar
1 citations
Measurement Energy
Optimal Power Flow Distribution
0.73
article

Optimal VAr management of a large power network using most efficient method of weak node detection

B. Bhattacharyya, Suraj Kumar Rajbhar
article en
1 citations

Abstract

A robust method for weak node detection for optimal VAr allocation has been proposed in this research. Modal or eigenvalue analysis, loss-sensitivity analysis, power flow analysis, L-index, and fast voltage stability index methods were employed to identify weak nodes in medium and large power networks using IEEE 57 and IEEE 118 bus systems. After identifying the locations for shunt VAr allocation, several standard optimization techniques i.e. Genetic Algorithm, Differential Evolution, Particle Swarm Optimization, Teaching-Learning-Based Optimization, Big Bang-Big Crunch, Krill Herd Algorithm, and Sine-Cosine Algorithm were then applied for optimal reactive power planning. These methods were aimed to coordinate VAr injections by shunt capacitors at weak nodes with existing VAr sources such as generators and On-Load Tap Changers. A comprehensive study of various standard detection techniques and their usefulness in power system planning is presented by the authors. Finally, authors deduced LSI (Line Stability Index) method of weak node detection was the most accurate method for weak node detection. Carrying out the proposed methodology, the total active power loss with GA & DE was found as 0.2348 p.u. & 0.2351 p.u. respectively for IEEE 57 bus test network and total operating cost was found as $1.2344 × 10 7 for GA & $1.2357 × 10 7 for DE. Similarly, for the IEEE 118-bus test network, the active power loss reported under GA and DE was 1.3295 p.u. each, with corresponding operating costs of $6.9885 × 10 7 and $6.9880 × 10 7 , respectively. This research offers a comprehensive framework for reducing operating cost and active power loss in reactive power planning. • Detection of weak nodes of a large power network. • Proposition of optimal VAr adjustments by the OLTC's, generators, and the shunt VAr injection at weak nodes. • Use of different optimization techniques to accomplish the task. • Comparative analysis of different techniques on the basis of the results obtained. • Deduction of loss and cost minimum configuration of the power network.

Measurement EnergyVol. 8
Indian Institute of Technology Dhanbad (IN)
Openalex Percentile: Top 22%
Optimal Power Flow Distribution
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.