Camera-based respiration rate monitoring using informative frame extraction

Camera-based monitoring shows potential for continuous respiration rate measurement in clinical settings. The main cause of errors in camera-based respiration rate measurement using optical flow is non-breathing motion, which disturbs the measurement of the breathing motion. To prevent this, uninformative video frames containing non-breathing motion should be detected and removed from consideration for respiration rate extraction. Currently, signal quality metrics or global motion detection are used to detect non-breathing motion, but these methods have limitations when applied in clinical settings. Therefore, in this research, we propose a new informativeness metric for optical flow based respiration rate monitoring. This metric exploits the residual error of the optical flow fit for determining the presence of non-breathing motion on a per breath basis. This new metric is evaluated on a clinical dataset that contains RGB videos of 25 ICU patients. We find that a 3 breaths/min agreement of 98.7% and a mean absolute error of 0.21 breaths/min is achieved across all patients. These results show that using our new informativeness metric, we can achieve highly accurate camera-based respiration rate monitoring without relying on assumptions on signal quality or waveform morphology. • Propose a novel informativeness metric using optical flow error for respiration monitoring. • Accurately detects and excludes non-breathing motion on a per-breath basis. • No assumptions are made on waveform morphology or regularity of the respiration. • Evaluated on RGB video recordings from 25 ICU patients in a real clinical setting. • Achieves 98.7% 3 breaths/min agreement and mean absolute error of 0.21 breaths/min.

Authors

Institutions

Publication Details

Journal
Biomedical Signal Processing and Control
Published
2025-11-09
DOI
https://doi.org/10.1016/j.bspc.2025.109119
Citations
1
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Camera-based respiration rate monitoring using informative frame extraction

Rik van Esch, Leon Montenij, Svitlana Zinger, R. Arthur Bouwman et al.
1 citations
Biomedical Signal Processing and Control
Non-Invasive Vital Sign Monitoring
0.67
article

Camera-based respiration rate monitoring using informative frame extraction

Rik van Esch, Leon Montenij, Svitlana Zinger, R. Arthur Bouwman, Sander Stuijk, J.W.M. Bergmans, Iris Cramer, Carla Kloeze, Cindy Verstappen, Lukas Dekker
article en
1 citations

Abstract

Camera-based monitoring shows potential for continuous respiration rate measurement in clinical settings. The main cause of errors in camera-based respiration rate measurement using optical flow is non-breathing motion, which disturbs the measurement of the breathing motion. To prevent this, uninformative video frames containing non-breathing motion should be detected and removed from consideration for respiration rate extraction. Currently, signal quality metrics or global motion detection are used to detect non-breathing motion, but these methods have limitations when applied in clinical settings. Therefore, in this research, we propose a new informativeness metric for optical flow based respiration rate monitoring. This metric exploits the residual error of the optical flow fit for determining the presence of non-breathing motion on a per breath basis. This new metric is evaluated on a clinical dataset that contains RGB videos of 25 ICU patients. We find that a 3 breaths/min agreement of 98.7% and a mean absolute error of 0.21 breaths/min is achieved across all patients. These results show that using our new informativeness metric, we can achieve highly accurate camera-based respiration rate monitoring without relying on assumptions on signal quality or waveform morphology. • Propose a novel informativeness metric using optical flow error for respiration monitoring. • Accurately detects and excludes non-breathing motion on a per-breath basis. • No assumptions are made on waveform morphology or regularity of the respiration. • Evaluated on RGB video recordings from 25 ICU patients in a real clinical setting. • Achieves 98.7% 3 breaths/min agreement and mean absolute error of 0.21 breaths/min.

Biomedical Signal Processing and ControlVol. 113
Radboud University Nijmegen (NL), Catharina Ziekenhuis (NL), Eindhoven University of Technology (NL)
Dutch Cardiovascular Alliance, ZonMw, Hartstichting, Nederlandse Organisatie voor Wetenschappelijk Onderzoek
Openalex Percentile: Top 25%
Non-Invasive Vital Sign Monitoring
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.