Self-Supervised Gait Event Detection from Smartphone IMUs for Human Performance and Sports Medicine

Background: Gait event detection from inertial sensors offers scalable insights into locomotor health, with applications in clinical monitoring and mobile health. However, supervised methods are limited by scarce annotations, device variability, and sensor placement shifts. This in silico study evaluates self-supervised learning (SSL) as a resource-efficient strategy to improve robustness and generalizability. Methods: Six public smartphone and wearable inertial measurements unit (IMU) datasets (WISDM, PAMAP2, KU-HAR, mHealth, OPPORTUNITY, RWHAR) were harmonized within a unified deep learning pipeline. Models were pretrained on unlabeled windows using contrastive SSL with sensor-aware augmentations, then fine-tuned with varying label fractions. Experiments systematically assessed included (1) pretraining scale, (2) label efficiency, (3) augmentation contributions, (4) device/placement shifts, (5) sampling-rate sensitivity, and (6) backbone comparisons (CNN, TCN, BiLSTM, Transformer). Results: SSL consistently outperformed supervised baselines. Pretraining yielded accuracy gains of ΔF1 +0.08–0.15 and reduced stride-time error by −8 to −12 ms. SSL cut label needs by up to 95%, achieving competitive performance with only 5–10% labeled data. Sensor-aware augmentations, particularly axis-swap and drift, drove the strongest transfer gains. Robustness was maintained across sampling rates (25–100 Hz) and device/placement shifts. CNNs and TCNs offered the best efficiency–accuracy trade-offs, while Transformers delivered the highest accuracy at greater cost. Conclusions: This computational analysis across six datasets shows SSL enhances gait event detection with improved accuracy, efficiency, and robustness under minimal supervision, establishing a scalable framework for human performance and sports medicine in clinical and mobile health applications.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-11-11
DOI
https://doi.org/10.3390/app152211974
Citations
5
Primary Topic
Balance, Gait, and Falls Prevention
Type
article
Field-Weighted Citation Impact
23.80
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Self-Supervised Gait Event Detection from Smartphone IMUs for Human Performance and Sports Medicine

Dan Cristian Mănescu, Andreea Maria Mănescu
5 citations
Applied Sciences
Balance, Gait, and Falls Prevention
23.80
article

Self-Supervised Gait Event Detection from Smartphone IMUs for Human Performance and Sports Medicine

Dan Cristian Mănescu, Andreea Maria Mănescu
article en
5 citations

Abstract

Background: Gait event detection from inertial sensors offers scalable insights into locomotor health, with applications in clinical monitoring and mobile health. However, supervised methods are limited by scarce annotations, device variability, and sensor placement shifts. This in silico study evaluates self-supervised learning (SSL) as a resource-efficient strategy to improve robustness and generalizability. Methods: Six public smartphone and wearable inertial measurements unit (IMU) datasets (WISDM, PAMAP2, KU-HAR, mHealth, OPPORTUNITY, RWHAR) were harmonized within a unified deep learning pipeline. Models were pretrained on unlabeled windows using contrastive SSL with sensor-aware augmentations, then fine-tuned with varying label fractions. Experiments systematically assessed included (1) pretraining scale, (2) label efficiency, (3) augmentation contributions, (4) device/placement shifts, (5) sampling-rate sensitivity, and (6) backbone comparisons (CNN, TCN, BiLSTM, Transformer). Results: SSL consistently outperformed supervised baselines. Pretraining yielded accuracy gains of ΔF1 +0.08–0.15 and reduced stride-time error by −8 to −12 ms. SSL cut label needs by up to 95%, achieving competitive performance with only 5–10% labeled data. Sensor-aware augmentations, particularly axis-swap and drift, drove the strongest transfer gains. Robustness was maintained across sampling rates (25–100 Hz) and device/placement shifts. CNNs and TCNs offered the best efficiency–accuracy trade-offs, while Transformers delivered the highest accuracy at greater cost. Conclusions: This computational analysis across six datasets shows SSL enhances gait event detection with improved accuracy, efficiency, and robustness under minimal supervision, establishing a scalable framework for human performance and sports medicine in clinical and mobile health applications.

Applied SciencesVol. 15(22)
Bucharest University of Economic Studies (RO)
Openalex Percentile: Top 1%
Balance, Gait, and Falls Prevention
23.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.