High Biocompatible Janus Adhesive Bioelectronics Patch Enables Reliable and Stable Pathological Cardiac Electrophysiological Mapping

Abstract Achieving cardiac electrophysiological labeling with high stability, high fidelity and high resolution still faces significant challenges. Current electrophysiological monitoring is limited by the interference of complex pathologic microenvironments or electromechanical uncoupling of the wet beating heart, making it difficult to ensure the stability and fidelity of signal acquisition. Thus, a highly biocompatible stretchable bioelectronic patch based on asymmetric Janus interface properties is presented, which can realize accurate and stable real‐time in vivo electrophysiological signal acquisition. This Janus adhesive bioelectronic patch significantly reduces mechanical mismatch at the tissue‐device interface, which allows for a highly conformal and tight interfacial coupling with dynamically beating cardiac tissue. This Janus interface design not only effectively inhibits the inflammatory response but also significantly reduces the risk of thoracic adhesion, thus dramatically improving the reliability and accuracy of signal acquisition. Experiments performed in two different Sprague‐Dawley rat models of left ventricular myocardial infarction and right ventricular hypertrophy demonstrated that the Janus bioelectronic patch is able to precisely localize the spatial and temporal characteristics of lesion occurrence, enabling accurate monitoring of the pathological process. Moreover, the patch exhibits excellent mechanical‐electrical stability throughout the cardiac cycle and achieves long‐term, reliable electrophysiological signal acquisition by maintaining continuous and stable interfacial contact with myocardial tissue.

Authors

Institutions

Publication Details

Journal
Advanced Functional Materials
Published
2025-11-13
DOI
https://doi.org/10.1002/adfm.202511531
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High Biocompatible Janus Adhesive Bioelectronics Patch Enables Reliable and Stable Pathological Cardiac Electrophysiological Mapping

Haibing Xu, Honghao Hou, Shiqi Guo, Rurong Lin et al.
Advanced Functional Materials
Advanced Sensor and Energy Harvesting Materials
article

High Biocompatible Janus Adhesive Bioelectronics Patch Enables Reliable and Stable Pathological Cardiac Electrophysiological Mapping

Haibing Xu, Honghao Hou, Shiqi Guo, Rurong Lin, Feng Xu, Chunyi Pu, Mengli Sui, Pengfei Wang, Jie Zhang, Shuai Liu, Nian Zhang, Dong Yang, Yanni Han, Si Shen
article en

Abstract

Abstract Achieving cardiac electrophysiological labeling with high stability, high fidelity and high resolution still faces significant challenges. Current electrophysiological monitoring is limited by the interference of complex pathologic microenvironments or electromechanical uncoupling of the wet beating heart, making it difficult to ensure the stability and fidelity of signal acquisition. Thus, a highly biocompatible stretchable bioelectronic patch based on asymmetric Janus interface properties is presented, which can realize accurate and stable real‐time in vivo electrophysiological signal acquisition. This Janus adhesive bioelectronic patch significantly reduces mechanical mismatch at the tissue‐device interface, which allows for a highly conformal and tight interfacial coupling with dynamically beating cardiac tissue. This Janus interface design not only effectively inhibits the inflammatory response but also significantly reduces the risk of thoracic adhesion, thus dramatically improving the reliability and accuracy of signal acquisition. Experiments performed in two different Sprague‐Dawley rat models of left ventricular myocardial infarction and right ventricular hypertrophy demonstrated that the Janus bioelectronic patch is able to precisely localize the spatial and temporal characteristics of lesion occurrence, enabling accurate monitoring of the pathological process. Moreover, the patch exhibits excellent mechanical‐electrical stability throughout the cardiac cycle and achieves long‐term, reliable electrophysiological signal acquisition by maintaining continuous and stable interfacial contact with myocardial tissue.

Advanced Functional MaterialsVol. 36(6)
University of Science and Technology of China (CN), Harvard University (US), Hefei University of Technology (CN), Third Affiliated Hospital of Southern Medical University (CN), Zhujiang Hospital (CN), Shanghai Center for Brain Science and Brain-Inspired Technology (CN), Southern Medical University (CN), Xi'an Jiaotong University (CN)
National Natural Science Foundation of China, Southern Medical University, Basic and Applied Basic Research Foundation of Guangdong Province
Openalex Percentile: Top 67%
Advanced Sensor and Energy Harvesting Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.