BPEI-Based N-Doped Carbon Dots with Sensitive and Selective Cu2+ Ion-Sensing Ability

In this research, we examined the potential sensor characteristics of branched polyethyleneimine (BPEI)-derived carbon dots (CDs) synthesized using BPEI as a nitrogen source and citric acid (CA) as a carbon source, specifically for the recognition of various metal ions. Among the BPEI CDs produced with different amounts of BPEI to CA BPEI:CA ratios of 0.5:1, 1:1, and 2:1 <i>w</i>/<i>w</i>, named as BPEI<sup>0.5</sup> CD, BPEI<sup>1</sup> CD, and BPEI<sup>2</sup> CD, respectively. The BPEI<sup>0.5</sup> CD, which contains the least BPEI, exhibited the highest fluorescence intensity: 50,300 a.u. in a 0.6 mg/mL solution were recorded as λ<sub>em</sub>: 420 nm at λ<sub>ex</sub>: 360 nm and 600 V PMT voltage with 5 nm of slit width for both excitation and emission. We investigated the fluorescence variations in BPEI CD-based CDs in 2 mL solutions containing Cd<sup>2+</sup>, Co<sup>2+</sup>, Cu<sup>2+</sup>, Ni<sup>2+</sup>, and Pb<sup>2+</sup> metal ions at various concentrations. Amongst these metal ions, the most pronounced sensitivity was noted for Cu<sup>2+</sup> ions with a limit of detection (LOD) value of 0.39 ppm. For BPEI CDs created with BPEI:CA ratios of 0.5:1, 1:1, and 2:1 <i>w</i>/<i>w</i>, the sensitivity to Cu<sup>2+</sup> ions increased with a higher BPEI ratio, with a LOD value of 0.30 ppm recorded for BPEI<sup>2</sup> CDs. Moreover, Cu<sup>2+</sup> ion solutions were prepared from various salts, including chloride, acetate, nitrate, and sulfate; aside from some fluorescence variation observed for BPEI<sup>0.5</sup> CDs, no significant difference in BPEI CD fluorescence change was observed with the use of the various salt solutions of Cu<sup>2+</sup> ion. In quenching experiments conducted on mixtures of Cd<sup>2+</sup>, Co<sup>2+</sup>, Cu<sup>2+</sup>, Ni<sup>2+</sup>, and Pb<sup>2+</sup> metal ions with Cu<sup>2+</sup>, it was noted that BPEI CDs displayed selectivity for Cu<sup>2+</sup> ions. Furthermore, the structures of BPEI CDs have been effectively utilized in real water samples, such as tap water and seawater, demonstrating a quenching capability of over 65% in the presence of 50 ppm Cu<sup>2+</sup> ions.

Authors

Institutions

Publication Details

Journal
Micromachines
Published
2025-11-13
DOI
https://doi.org/10.3390/mi16111275
Primary Topic
Carbon and Quantum Dots Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

BPEI-Based N-Doped Carbon Dots with Sensitive and Selective Cu2+ Ion-Sensing Ability

Nurettin Şahiner, Şahin Demirci, Jorge H. Torres
Micromachines
Carbon and Quantum Dots Applications
article

BPEI-Based N-Doped Carbon Dots with Sensitive and Selective Cu2+ Ion-Sensing Ability

Nurettin Şahiner, Şahin Demirci, Jorge H. Torres
article en

Abstract

In this research, we examined the potential sensor characteristics of branched polyethyleneimine (BPEI)-derived carbon dots (CDs) synthesized using BPEI as a nitrogen source and citric acid (CA) as a carbon source, specifically for the recognition of various metal ions. Among the BPEI CDs produced with different amounts of BPEI to CA BPEI:CA ratios of 0.5:1, 1:1, and 2:1 <i>w</i>/<i>w</i>, named as BPEI<sup>0.5</sup> CD, BPEI<sup>1</sup> CD, and BPEI<sup>2</sup> CD, respectively. The BPEI<sup>0.5</sup> CD, which contains the least BPEI, exhibited the highest fluorescence intensity: 50,300 a.u. in a 0.6 mg/mL solution were recorded as λ<sub>em</sub>: 420 nm at λ<sub>ex</sub>: 360 nm and 600 V PMT voltage with 5 nm of slit width for both excitation and emission. We investigated the fluorescence variations in BPEI CD-based CDs in 2 mL solutions containing Cd<sup>2+</sup>, Co<sup>2+</sup>, Cu<sup>2+</sup>, Ni<sup>2+</sup>, and Pb<sup>2+</sup> metal ions at various concentrations. Amongst these metal ions, the most pronounced sensitivity was noted for Cu<sup>2+</sup> ions with a limit of detection (LOD) value of 0.39 ppm. For BPEI CDs created with BPEI:CA ratios of 0.5:1, 1:1, and 2:1 <i>w</i>/<i>w</i>, the sensitivity to Cu<sup>2+</sup> ions increased with a higher BPEI ratio, with a LOD value of 0.30 ppm recorded for BPEI<sup>2</sup> CDs. Moreover, Cu<sup>2+</sup> ion solutions were prepared from various salts, including chloride, acetate, nitrate, and sulfate; aside from some fluorescence variation observed for BPEI<sup>0.5</sup> CDs, no significant difference in BPEI CD fluorescence change was observed with the use of the various salt solutions of Cu<sup>2+</sup> ion. In quenching experiments conducted on mixtures of Cd<sup>2+</sup>, Co<sup>2+</sup>, Cu<sup>2+</sup>, Ni<sup>2+</sup>, and Pb<sup>2+</sup> metal ions with Cu<sup>2+</sup>, it was noted that BPEI CDs displayed selectivity for Cu<sup>2+</sup> ions. Furthermore, the structures of BPEI CDs have been effectively utilized in real water samples, such as tap water and seawater, demonstrating a quenching capability of over 65% in the presence of 50 ppm Cu<sup>2+</sup> ions.

MicromachinesVol. 16(11)
Çanakkale Onsekiz Mart Üniversitesi (TR), Istanbul Aydın University (TR), Florida Gulf Coast University (US)
Türkiye Bilimler Akademisi
Openalex Percentile: Top 73%
Carbon and Quantum Dots Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.