A novel propane – CO2 refrigeration system for mobile insulated boxes in last mile delivery

• R290-R744 indirect expansion cooling unit for insulated boxes with TES • R290 confined in the primary circuit, avoiding open connections or leaks in the box • Dynamic numerical model of the baseline unit validated against experimental data • Phase-change secondary flow avoids subcooling in eutectic plates • Pulldown COP same as baseline, but annual emissions reduced by 69.6% thanks to naturals The transport refrigeration industry predominantly relies on mechanical vapor compression systems, which still use refrigerants with high environmental impact, for both long and short distance transportation. In short distance application, the integration of thermal energy storage (TES) and the use of natural refrigerants represent a promising path in reducing the environmental impact of the sector. This paper presents an innovative indirect expansion refrigeration system utilizing natural refrigerants (R290 and R744) to freeze eutectic plates, located inside an insulated box, designed for last-mile delivery of frozen food. A numerical model is developed and first validated against experimental data available for the baseline R452A solution, achieving a -1.2% error on the estimated energy consumption over the entire pulldown. When considering the new system, numerical simulations of a 36-hours pulldown show that, despite delivering the same cooling energy to the eutectic plates (-0.6 % compared to the baseline), the R290-R744 system can achieve a better distribution of the cooling effect in the eutectic plates, avoiding subcooling. During a 36-hours pulldown, the R290-R744 can perform with the same overall COP (0.79). However, on an annual basis, the use of natural refrigerants instead of synthetics allows achieving a reduction of the system overall carbon footprint equal to -69.6%.

Authors

Institutions

Publication Details

Journal
International Journal of Refrigeration
Published
2025-11-13
DOI
https://doi.org/10.1016/j.ijrefrig.2025.10.027
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel propane – CO2 refrigeration system for mobile insulated boxes in last mile delivery

Silvia Minetto, Antonio Rossetti, Sergio Marinetti, Francesco Fabris et al.
International Journal of Refrigeration
Refrigeration and Air Conditioning Technologies
article

A novel propane – CO2 refrigeration system for mobile insulated boxes in last mile delivery

Silvia Minetto, Antonio Rossetti, Sergio Marinetti, Francesco Fabris, Wasim Shah
article en

Abstract

• R290-R744 indirect expansion cooling unit for insulated boxes with TES • R290 confined in the primary circuit, avoiding open connections or leaks in the box • Dynamic numerical model of the baseline unit validated against experimental data • Phase-change secondary flow avoids subcooling in eutectic plates • Pulldown COP same as baseline, but annual emissions reduced by 69.6% thanks to naturals The transport refrigeration industry predominantly relies on mechanical vapor compression systems, which still use refrigerants with high environmental impact, for both long and short distance transportation. In short distance application, the integration of thermal energy storage (TES) and the use of natural refrigerants represent a promising path in reducing the environmental impact of the sector. This paper presents an innovative indirect expansion refrigeration system utilizing natural refrigerants (R290 and R744) to freeze eutectic plates, located inside an insulated box, designed for last-mile delivery of frozen food. A numerical model is developed and first validated against experimental data available for the baseline R452A solution, achieving a -1.2% error on the estimated energy consumption over the entire pulldown. When considering the new system, numerical simulations of a 36-hours pulldown show that, despite delivering the same cooling energy to the eutectic plates (-0.6 % compared to the baseline), the R290-R744 system can achieve a better distribution of the cooling effect in the eutectic plates, avoiding subcooling. During a 36-hours pulldown, the R290-R744 can perform with the same overall COP (0.79). However, on an annual basis, the use of natural refrigerants instead of synthetics allows achieving a reduction of the system overall carbon footprint equal to -69.6%.

International Journal of RefrigerationVol. 182
University of Padua (IT), Construction Technologies Institute (IT)
Openalex Percentile: Top 64%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.