Techno-economic feasibility of solar power penetration involving transmission losses compensation

Solar power has become a popular renewable energy source, and the integration of solar power plants into a power grid has various technical, economic, and environmental implications. This research provides a new perspective on investigating the economic and environmental impact on a power grid. The effectiveness of this method is tested in a solar photovoltaic system connected to a grid of 8-bus. Simultaneous results show that the integration increases bus voltage by up to 0.4 kV and reduces transmission losses to 181.23 MWh/year, with total generated power at the slack bus reaching 3266.75 MWh/year. The reduction in transmission losses saves approximately USD 1,468,730.80 in operational costs. The payback period is 3.78 years, and the investment proves profitable, with a positive net present value. This reduction also reduces fuel consumption by about 345.78 kiloliters/year, mitigating climate change by preventing 898.38 tons CO2e/year of greenhouse gas emissions.

Authors

Institutions

Publication Details

Journal
Cogent Engineering
Published
2025-11-13
DOI
https://doi.org/10.1080/23311916.2025.2584594
Primary Topic
Optimal Power Flow Distribution
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Techno-economic feasibility of solar power penetration involving transmission losses compensation

Adelhard Beni Rehiara, Sabar Setiawidayat
Cogent Engineering
Optimal Power Flow Distribution
article

Techno-economic feasibility of solar power penetration involving transmission losses compensation

Adelhard Beni Rehiara, Sabar Setiawidayat
article en

Abstract

Solar power has become a popular renewable energy source, and the integration of solar power plants into a power grid has various technical, economic, and environmental implications. This research provides a new perspective on investigating the economic and environmental impact on a power grid. The effectiveness of this method is tested in a solar photovoltaic system connected to a grid of 8-bus. Simultaneous results show that the integration increases bus voltage by up to 0.4 kV and reduces transmission losses to 181.23 MWh/year, with total generated power at the slack bus reaching 3266.75 MWh/year. The reduction in transmission losses saves approximately USD 1,468,730.80 in operational costs. The payback period is 3.78 years, and the investment proves profitable, with a positive net present value. This reduction also reduces fuel consumption by about 345.78 kiloliters/year, mitigating climate change by preventing 898.38 tons CO2e/year of greenhouse gas emissions.

Cogent EngineeringVol. 12(1)
University of Papua New Guinea (PG), State University of Papua (ID), Tama University (JP), Universitas Widya Gama Malang (ID)
Openalex Percentile: Top 66%
Optimal Power Flow Distribution
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.