Systematic errors in isothermal titration calorimetry: The role of feedback power and effects of mixing and diffusion on concentrations

Using experiments based on the NaCl dilution calibration method, we examine several previously unstudied instrumental effects that can lead to systematic errors in isothermal titration calorimetry (ITC). We confirm earlier results that power feedback can affect estimated heats and find further that it can also affect cell temperature and introduce temperature "noise." To estimate effects from loss of titrant from the syringe through diffusion, and concentration changes in the cell from mixing with the overflow volume, we conduct experiments with injections separated by time intervals Δt from 8 to 60 min, giving run durations from 6 h to over 2 days. Because the effects are small, we have developed a global least-squares fitting algorithm to analyze 20 datasets simultaneously, from which three parameters governing diffusion and mixing ("leakage") are estimated, along with calibration parameters for heat and cell volume. Expressed as an effective volume loss from the syringe, Δv<sub>dif</sub> is found to be of order ∼0.03 μL per injection for NaCl into water. Its effect is predicted to be negligible in many ITC applications. The effects from leakage are more significant but their neglect is still predicted to affect both NaCl calibration and 1:1 binding results by ∼1 %, which is marginally significant for calibration but seldom so for 1:1 binding. The calibration results for the cell volume V<sub>0</sub> are particularly sensitive to temperature and to the literature source for the relative molar enthalpy function for NaCl(aq).

Authors

Institutions

Publication Details

Journal
Analytical Biochemistry
Published
2025-11-12
DOI
https://doi.org/10.1016/j.ab.2025.116010
Primary Topic
thermodynamics and calorimetric analyses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Systematic errors in isothermal titration calorimetry: The role of feedback power and effects of mixing and diffusion on concentrations

Marija Bešter‐Rogač, Žiga Medoš, Joel Tellinghuisen, Epameinondas Leontidis
Analytical Biochemistry
thermodynamics and calorimetric analyses
article

Systematic errors in isothermal titration calorimetry: The role of feedback power and effects of mixing and diffusion on concentrations

Marija Bešter‐Rogač, Žiga Medoš, Joel Tellinghuisen, Epameinondas Leontidis
article en

Abstract

Using experiments based on the NaCl dilution calibration method, we examine several previously unstudied instrumental effects that can lead to systematic errors in isothermal titration calorimetry (ITC). We confirm earlier results that power feedback can affect estimated heats and find further that it can also affect cell temperature and introduce temperature "noise." To estimate effects from loss of titrant from the syringe through diffusion, and concentration changes in the cell from mixing with the overflow volume, we conduct experiments with injections separated by time intervals Δt from 8 to 60 min, giving run durations from 6 h to over 2 days. Because the effects are small, we have developed a global least-squares fitting algorithm to analyze 20 datasets simultaneously, from which three parameters governing diffusion and mixing ("leakage") are estimated, along with calibration parameters for heat and cell volume. Expressed as an effective volume loss from the syringe, Δv<sub>dif</sub> is found to be of order ∼0.03 μL per injection for NaCl into water. Its effect is predicted to be negligible in many ITC applications. The effects from leakage are more significant but their neglect is still predicted to affect both NaCl calibration and 1:1 binding results by ∼1 %, which is marginally significant for calibration but seldom so for 1:1 binding. The calibration results for the cell volume V<sub>0</sub> are particularly sensitive to temperature and to the literature source for the relative molar enthalpy function for NaCl(aq).

Analytical BiochemistryVol. 709
University of Ljubljana (SI), Vanderbilt University (US), University of Cyprus (CY)
Openalex Percentile: Top 69%
thermodynamics and calorimetric analyses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Systematic errors in isothermal titration calorimetry: The role of feedback power and effects of mixing and diffusion on concentrations — Marija Bešter‐Rogač, Žiga Medoš, et al. · Analytical Biochemistry (2025) | TGRS Research Map | TGRS