The New Surface-Modified Flow Diverter p48 MW HPC Device Implanted in Arteries under 2.0 mm Diameter for Treatment of Distal Intracranial Aneurysms

Preliminary studies on the new modified surface flow diverters (FD) have shown promising results in the treatment of distal aneurysms. However, there is a lack of data in the literature regarding the use of these devices in very small-caliber arteries. The aim of this study was to analyze the safety and efficacy of the p48 MW HPC device (Wallaby-phenox, Bochum, Germany) device in the treatment of intracranial aneurysms associated with parent arteries with a diameter of <2.0 mm.Sixteen patients were prospectively evaluated from November 2019 to July 2023. All patients underwent follow-ups at 1, 6, and 12 months. Safety was assessed using the modified Rankin Scale and the National Institutes of Health Stroke Scale. Efficacy was defined as complete (grade D) or partial (grade C) aneurysm occlusion, as assessed by the O'Kelly-Marotta scale (OKM).The mean proximal and distal artery diameters were 1.61 mm (1.3-1.9) and 1.5 mm (1.0-1.8), respectively. All procedures were performed with technical success, and no severe adverse events occurred. At the 12-month follow-up, no patients experienced serious adverse events, new neurological symptoms, or deficits. At this stage, seven aneurysms were completely occluded (OKM grade D: 43.7%), and four aneurysms showed entry remnant contrast (OKM grade C: 25%).The treatment of distal unruptured aneurysms with the p48 MW HPC device device appears to be safe in vessels with a diameter of <2 mm. Larger studies with long-term follow-ups are necessary to better clarify the outcomes reported.

Authors

Institutions

Publication Details

Journal
Journal of Neurological Surgery Part A Central European Neurosurgery
Published
2025-11-13
DOI
https://doi.org/10.1055/a-2697-4429
Primary Topic
Intracranial Aneurysms: Treatment and Complications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The New Surface-Modified Flow Diverter p48 MW HPC Device Implanted in Arteries under 2.0 mm Diameter for Treatment of Distal Intracranial Aneurysms

Benedicto Oscar Colli, Daniel Giansante Abud, Guilherme Seizem Nakiri, Luís Henrique de Castro-Afonso et al.
Journal of Neurological Surgery Part A Central European Neurosurgery
Intracranial Aneurysms: Treatment and Complications
article

The New Surface-Modified Flow Diverter p48 MW HPC Device Implanted in Arteries under 2.0 mm Diameter for Treatment of Distal Intracranial Aneurysms

Benedicto Oscar Colli, Daniel Giansante Abud, Guilherme Seizem Nakiri, Luís Henrique de Castro-Afonso, Paulo R. Fernandes, Ricardo Santos de Oliveira
article en

Abstract

Preliminary studies on the new modified surface flow diverters (FD) have shown promising results in the treatment of distal aneurysms. However, there is a lack of data in the literature regarding the use of these devices in very small-caliber arteries. The aim of this study was to analyze the safety and efficacy of the p48 MW HPC device (Wallaby-phenox, Bochum, Germany) device in the treatment of intracranial aneurysms associated with parent arteries with a diameter of <2.0 mm.Sixteen patients were prospectively evaluated from November 2019 to July 2023. All patients underwent follow-ups at 1, 6, and 12 months. Safety was assessed using the modified Rankin Scale and the National Institutes of Health Stroke Scale. Efficacy was defined as complete (grade D) or partial (grade C) aneurysm occlusion, as assessed by the O'Kelly-Marotta scale (OKM).The mean proximal and distal artery diameters were 1.61 mm (1.3-1.9) and 1.5 mm (1.0-1.8), respectively. All procedures were performed with technical success, and no severe adverse events occurred. At the 12-month follow-up, no patients experienced serious adverse events, new neurological symptoms, or deficits. At this stage, seven aneurysms were completely occluded (OKM grade D: 43.7%), and four aneurysms showed entry remnant contrast (OKM grade C: 25%).The treatment of distal unruptured aneurysms with the p48 MW HPC device device appears to be safe in vessels with a diameter of <2 mm. Larger studies with long-term follow-ups are necessary to better clarify the outcomes reported.

Journal of Neurological Surgery Part A Central European Neurosurgery
Universidade de Ribeirão Preto (BR), Hospital Bandeirantes (BR)
Openalex Percentile: Top 53%
Intracranial Aneurysms: Treatment and Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.