Simultaneous Electrochemical Sensing of Ultra-Trace Multiple Heavy Metals Using Metal–Organic Frameworks-Graphene Oxide Nanocomposite-Modified Electrodes

The relentless pace of industrialization has significantly exacerbated environmental pollution, with heavy-metal ions (HMIs) emerging as some of the most persistent and toxic pollutants in natural ecosystems. Growing concerns over environmental pollution have created a need for advanced sensing technologies that offer superior sensing sensitivity, selectivity, and reliability. This work reports the development of an electrochemical sensor based on a UiO-66-NH<sub>2</sub>(Zr) metal-organic framework (MOF)/graphene oxide (GO) nanocomposite for the simultaneous detection of HMIs in aqueous environments. Using one-pot hydrothermal synthesis, MOFs and conductive GO materials were integrated into a single nanostructure via <i>in situ</i> growth of the UiO-66-NH<sub>2</sub>(Zr) MOF on the GO matrix, resulting in the formation of a stable MOF/GO nanocomposite with enhanced conductivity and increased number of effective reaction sites. The amino groups (-NH<sub>2</sub>) on UiO-66-NH<sub>2</sub>(Zr) porous materials serve as adsorption sites to capture HMIs. The morphological, structural, and electrochemical properties of the UiO-66-NH<sub>2</sub>(Zr)-GO nanocomposite were examined by using scanning electron microscopy/energy-dispersive spectroscopy (SEM/EDS), powder X-ray diffraction (PXRD), Fourier transform infrared (FTIR) spectroscopy, cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). Differential pulse anodic stripping voltammetry (DPASV) was subsequently employed for the detection of heavy-metal ions over nanomolar to micromolar concentration ranges using a UiO-66-NH<sub>2</sub>(Zr)-GO-modified glassy carbon (GC) electrode. The electrochemical sensor developed in this study was successfully utilized for the selective and concurrent detection of multiple HMIs, namely, copper ion (Cu<sup>2+</sup>), cadmium ion (Cd<sup>2+</sup>), and lead ion (Pb<sup>2+</sup>) in electrolyte solution. The sensor demonstrated achieving high selectivity and sensitivity (1.30 μA μM<sup>-1</sup> for Cu<sup>2+</sup>, 0.50 μA μM<sup>-1</sup> for Cd<sup>2+</sup>, and 12.38 μA μM<sup>-1</sup> for Pb<sup>2+</sup>) with low limit of detection (LOD) (0.59 ng/mL for Cu<sup>2+</sup>, 0.84 ng/mL for Cd<sup>2+</sup>, and 2.9 ng/mL for Pb<sup>2+</sup>), and observed ≥85% reproducibility. The sensor demonstrated excellent long-term stability and operated effectively within a temperature range of 283-313 K, enabling the simultaneous detection of multiple heavy-metal ions from small sample volumes. The developed electrochemical method can equally be employed to detect HMIs at trace (parts-per-billion (ppb)) levels in diverse environmental matrices such as lake, river, tap water, river sediments, and wastewater.

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2025-11-13
DOI
https://doi.org/10.1021/acsomega.5c07592
Citations
3
Primary Topic
Electrochemical Analysis and Applications
Type
article
Field-Weighted Citation Impact
1.55
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simultaneous Electrochemical Sensing of Ultra-Trace Multiple Heavy Metals Using Metal–Organic Frameworks-Graphene Oxide Nanocomposite-Modified Electrodes

Jamal Uddin, Mohammed M. Rahman, Maksudul M. Alam, E. M. Ford et al.
3 citations
ACS Omega
Electrochemical Analysis and Applications
1.55
article

Simultaneous Electrochemical Sensing of Ultra-Trace Multiple Heavy Metals Using Metal–Organic Frameworks-Graphene Oxide Nanocomposite-Modified Electrodes

Jamal Uddin, Mohammed M. Rahman, Maksudul M. Alam, E. M. Ford, William Ghann, Charles C. Chusuei, Md Humayun Kabir, Meser M. Ali, Jacob A. Wolvington, Rashomi Mathanan, Kanyon Demonbreun
article en
3 citations

Abstract

The relentless pace of industrialization has significantly exacerbated environmental pollution, with heavy-metal ions (HMIs) emerging as some of the most persistent and toxic pollutants in natural ecosystems. Growing concerns over environmental pollution have created a need for advanced sensing technologies that offer superior sensing sensitivity, selectivity, and reliability. This work reports the development of an electrochemical sensor based on a UiO-66-NH<sub>2</sub>(Zr) metal-organic framework (MOF)/graphene oxide (GO) nanocomposite for the simultaneous detection of HMIs in aqueous environments. Using one-pot hydrothermal synthesis, MOFs and conductive GO materials were integrated into a single nanostructure via <i>in situ</i> growth of the UiO-66-NH<sub>2</sub>(Zr) MOF on the GO matrix, resulting in the formation of a stable MOF/GO nanocomposite with enhanced conductivity and increased number of effective reaction sites. The amino groups (-NH<sub>2</sub>) on UiO-66-NH<sub>2</sub>(Zr) porous materials serve as adsorption sites to capture HMIs. The morphological, structural, and electrochemical properties of the UiO-66-NH<sub>2</sub>(Zr)-GO nanocomposite were examined by using scanning electron microscopy/energy-dispersive spectroscopy (SEM/EDS), powder X-ray diffraction (PXRD), Fourier transform infrared (FTIR) spectroscopy, cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). Differential pulse anodic stripping voltammetry (DPASV) was subsequently employed for the detection of heavy-metal ions over nanomolar to micromolar concentration ranges using a UiO-66-NH<sub>2</sub>(Zr)-GO-modified glassy carbon (GC) electrode. The electrochemical sensor developed in this study was successfully utilized for the selective and concurrent detection of multiple HMIs, namely, copper ion (Cu<sup>2+</sup>), cadmium ion (Cd<sup>2+</sup>), and lead ion (Pb<sup>2+</sup>) in electrolyte solution. The sensor demonstrated achieving high selectivity and sensitivity (1.30 μA μM<sup>-1</sup> for Cu<sup>2+</sup>, 0.50 μA μM<sup>-1</sup> for Cd<sup>2+</sup>, and 12.38 μA μM<sup>-1</sup> for Pb<sup>2+</sup>) with low limit of detection (LOD) (0.59 ng/mL for Cu<sup>2+</sup>, 0.84 ng/mL for Cd<sup>2+</sup>, and 2.9 ng/mL for Pb<sup>2+</sup>), and observed ≥85% reproducibility. The sensor demonstrated excellent long-term stability and operated effectively within a temperature range of 283-313 K, enabling the simultaneous detection of multiple heavy-metal ions from small sample volumes. The developed electrochemical method can equally be employed to detect HMIs at trace (parts-per-billion (ppb)) levels in diverse environmental matrices such as lake, river, tap water, river sediments, and wastewater.

ACS OmegaVol. 10(46)
University of North Alabama (US), Middle Tennessee State University (US), King Abdulaziz University (SA), Wayne State University (US), The Barbara Ann Karmanos Cancer Institute (US), Applied Nanotech (United States) (US), InnoSense (United States) (US), Centre of Excellence for Advanced Materials (CN), Coppin State University (US)
Openalex Percentile: Top 16%
Electrochemical Analysis and Applications
1.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.