Measurement of microdosimetric spectra of high‐LET particle beams using the ENCORE detector

This study demonstrated that ENCORE can resolve microdosimetric spectra with high spatial and LET resolution across a range of ion energies. Measured <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:semantics> <mml:msub><mml:mover><mml:mi>y</mml:mi> <mml:mo>¯</mml:mo></mml:mover> <mml:mi>D</mml:mi></mml:msub> <mml:annotation>${\bar y_{\mathrm{D}}}$</mml:annotation></mml:semantics> </mml:math> values reasonably agreed with Monte Carlo simulations, validating the potential of ENCORE for position-resolved microdosimetry and model benchmarking in particle therapy.

Authors

Institutions

Publication Details

Journal
Medical Physics
Published
2025-11-01
DOI
https://doi.org/10.1002/mp.70150
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement of microdosimetric spectra of high‐LET particle beams using the ENCORE detector

Shannon Hartzell, Chris Beltran, S. Almaraz-Calderon, E. López-Saavedra et al.
Medical Physics
Radiation Therapy and Dosimetry
article

Measurement of microdosimetric spectra of high‐LET particle beams using the ENCORE detector

Shannon Hartzell, Chris Beltran, S. Almaraz-Calderon, E. López-Saavedra, Keith M. Furutani, I. Wiedenhöver, L. T. Baby
article en

Abstract

This study demonstrated that ENCORE can resolve microdosimetric spectra with high spatial and LET resolution across a range of ion energies. Measured <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:semantics> <mml:msub><mml:mover><mml:mi>y</mml:mi> <mml:mo>¯</mml:mo></mml:mover> <mml:mi>D</mml:mi></mml:msub> <mml:annotation>${\bar y_{\mathrm{D}}}$</mml:annotation></mml:semantics> </mml:math> values reasonably agreed with Monte Carlo simulations, validating the potential of ENCORE for position-resolved microdosimetry and model benchmarking in particle therapy.

Medical PhysicsVol. 52(11)
Florida State University (US), Argonne National Laboratory (US), Jacksonville College (US), Mayo Clinic in Florida (US)
Openalex Percentile: Top 51%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Measurement of microdosimetric spectra of high‐LET particle beams using the ENCORE detector — Shannon Hartzell, Chris Beltran, et al. · Medical Physics (2025) | TGRS Research Map | TGRS