Stress distribution and prosthesis deformation analysis of different bar materials considering weight in trefoil implant system under various loading conditions: a finite element study

This study evaluated seven bar materials-Titanium (Ti), Cobalt-Chromium (Co-Cr), Zirconia (Zr), Polyetheretherketone (PEEK), Carbon-Fiber-Reinforced PEEK (CFR-PEEK), 3D-printed resin (3D-Pr), and Polymethyl methacrylate (PMMA)-in the Trefoil implant system using three-dimensional finite element analysis under vertical and oblique loads. Stress distribution and prosthesis deformation were analyzed, and a Performance Index combining mass and deformation was calculated. Bar material mainly influenced deformation: metallic bars (Ti, Co-Cr, Zr) showed minimal, while non-metallic (3D-Pr, PMMA) showed higher deformation. Titanium had the best performance, followed by zirconia and CFR-PEEK. Selecting optimal bar materials enhances biomechanical efficiency in Trefoil prostheses.

Authors

Institutions

Publication Details

Journal
Computer Methods in Biomechanics & Biomedical Engineering
Published
2025-11-13
DOI
https://doi.org/10.1080/10255842.2025.2584392
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stress distribution and prosthesis deformation analysis of different bar materials considering weight in trefoil implant system under various loading conditions: a finite element study

Nagehan Baki, Mesut Tuzlalı
Computer Methods in Biomechanics & Biomedical Engineering
Dental Implant Techniques and Outcomes
article

Stress distribution and prosthesis deformation analysis of different bar materials considering weight in trefoil implant system under various loading conditions: a finite element study

Nagehan Baki, Mesut Tuzlalı
article en

Abstract

This study evaluated seven bar materials-Titanium (Ti), Cobalt-Chromium (Co-Cr), Zirconia (Zr), Polyetheretherketone (PEEK), Carbon-Fiber-Reinforced PEEK (CFR-PEEK), 3D-printed resin (3D-Pr), and Polymethyl methacrylate (PMMA)-in the Trefoil implant system using three-dimensional finite element analysis under vertical and oblique loads. Stress distribution and prosthesis deformation were analyzed, and a Performance Index combining mass and deformation was calculated. Bar material mainly influenced deformation: metallic bars (Ti, Co-Cr, Zr) showed minimal, while non-metallic (3D-Pr, PMMA) showed higher deformation. Titanium had the best performance, followed by zirconia and CFR-PEEK. Selecting optimal bar materials enhances biomechanical efficiency in Trefoil prostheses.

Computer Methods in Biomechanics & Biomedical Engineering
Inonu University (TR)
Openalex Percentile: Top 52%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Stress distribution and prosthesis deformation analysis of different bar materials considering weight in trefoil implant system under various loading conditions: a finite element study — Nagehan Baki, Mesut Tuzlalı · Computer Methods in Biomechanics & Biomedical Engineering (2025) | TGRS Research Map | TGRS