Recommended flow rate of the aluminum cyclone for improved exposure assessment

Samples of the respirable fraction of airborne particles to which workers are exposed are an important component of many health protection programs, especially in those workplaces where there is a risk of health problems from exposure to respirable crystalline silica. The most common technique for size-selection of the respirable dust fraction is to use a miniature cyclone preselector, many of which are based on the "Higgens-Dewell" (HD) design. A variant of the HD cyclone, commonly referred to as the "aluminum (or aluminium) cyclone," was developed in Scandinavia. Early work showed that a flow rate of 2.2 l min-1 would be appropriate to meet the size-separation convention standardized under the International Organization for Standardization (ISO), while a later, non-peer-reviewed study suggested 2.5 l min-1 and this flow rate is currently recommended by the manufacturers. The International Sampler Comparison Group is working on revising the European Standard EN13205 on sampler performance testing for consideration as an ISO standard. In this work, 5 aluminum cyclone units were tested at 2.5 l min-1 and the cyclones were further tested at 2.3 and 2.2 l min-1 to determine the optimal flow rate. While the flow rate of 2.3 l min-1 had the lowest overall mean bias, a flow rate of 2.2 l min-1 gave bias <±10% over the whole area of size distributions of interest. This supports earlier findings and suggests that 2.2 l min-1 is the most accurate flow rate for sampling with the aluminum cyclone. However, 2.3 l min-1 also meets the specification of EN13205 in that the area of bias >±10% is minimal. The consequence of continuing to use the aluminum cyclone at 2.5 l min-1 is an underestimate of respirable particles when compared with the ISO convention.

Authors

Institutions

Publication Details

Journal
Annals of Work Exposures and Health
Published
2025-10-19
DOI
https://doi.org/10.1093/annweh/wxaf075
Primary Topic
Occupational and environmental lung diseases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Recommended flow rate of the aluminum cyclone for improved exposure assessment

Emanuele Cauda, Taekhee Lee, Martin Harper, S Yang
Annals of Work Exposures and Health
Occupational and environmental lung diseases
article

Recommended flow rate of the aluminum cyclone for improved exposure assessment

Emanuele Cauda, Taekhee Lee, Martin Harper, S Yang
article en

Abstract

Samples of the respirable fraction of airborne particles to which workers are exposed are an important component of many health protection programs, especially in those workplaces where there is a risk of health problems from exposure to respirable crystalline silica. The most common technique for size-selection of the respirable dust fraction is to use a miniature cyclone preselector, many of which are based on the "Higgens-Dewell" (HD) design. A variant of the HD cyclone, commonly referred to as the "aluminum (or aluminium) cyclone," was developed in Scandinavia. Early work showed that a flow rate of 2.2 l min-1 would be appropriate to meet the size-separation convention standardized under the International Organization for Standardization (ISO), while a later, non-peer-reviewed study suggested 2.5 l min-1 and this flow rate is currently recommended by the manufacturers. The International Sampler Comparison Group is working on revising the European Standard EN13205 on sampler performance testing for consideration as an ISO standard. In this work, 5 aluminum cyclone units were tested at 2.5 l min-1 and the cyclones were further tested at 2.3 and 2.2 l min-1 to determine the optimal flow rate. While the flow rate of 2.3 l min-1 had the lowest overall mean bias, a flow rate of 2.2 l min-1 gave bias <±10% over the whole area of size distributions of interest. This supports earlier findings and suggests that 2.2 l min-1 is the most accurate flow rate for sampling with the aluminum cyclone. However, 2.3 l min-1 also meets the specification of EN13205 in that the area of bias >±10% is minimal. The consequence of continuing to use the aluminum cyclone at 2.5 l min-1 is an underestimate of respirable particles when compared with the ISO convention.

Annals of Work Exposures and HealthVol. 70(2)
National Institute for Occupational Safety and Health (US), University of Florida (US)
Openalex Percentile: Top 51%
Occupational and environmental lung diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.