Optimizing CT pulmonary angiography: comparison of radiation dose, contrast volume, and image quality between standard and low-dose protocols

Abstract Background Pulmonary embolism (PE) is a potentially life-threatening condition that requires prompt and accurate diagnosis. Computed tomography pulmonary angiography (CTPA) is the reference standard for PE detection; however, it carries risks of radiation exposure and contrast-induced nephropathy, particularly in younger patients and those requiring repeated scans. This study aimed to evaluate whether a combined low-dose, low-contrast CTPA protocol could achieve diagnostic image quality comparable to the standard protocol. Methods In this prospective comparative study, 44 patients with clinically suspected PE were enrolled. The control group ( n = 22) underwent standard CTPA (120 kVp, 90 mL contrast), while the experimental group ( n = 22) received an optimized protocol (100 kVp, 70 mL contrast, automatic tube current modulation, and 50% ASiR-V iterative reconstruction). Radiation dose parameters and contrast usage were recorded. Subjective image quality was graded by two blinded radiologists using a 5-point Likert scale, and quantitative metrics Hounsfield units (HU), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were compared between groups. Results The optimized protocol achieved a 39.6% reduction in effective dose (2.65 ± 0.54 mSv vs. 4.39 ± 0.62 mSv; p ≤ 0.001) and a 22.2% reduction in contrast volume (70 mL vs. 90 mL). Subjective image quality was comparable between groups ( p = 0.606). Quantitative analysis revealed no significant differences in SNR, CNR, or vascular attenuation ( p > 0.05). Interobserver agreement was excellent (ICC = 0.91). Conclusions A low-dose, low-contrast CTPA protocol can substantially reduce patient radiation and contrast exposure while maintaining diagnostic image quality. This approach supports the ALARA principle and may serve as a practical, cost-effective standard for routine PE imaging, especially in resource-limited or high-risk patient settings.

Authors

Institutions

Publication Details

Journal
The Egyptian Journal of Radiology and Nuclear Medicine
Published
2025-11-13
DOI
https://doi.org/10.1186/s43055-025-01631-w
Primary Topic
Venous Thromboembolism Diagnosis and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing CT pulmonary angiography: comparison of radiation dose, contrast volume, and image quality between standard and low-dose protocols

Mahadevappa Mahesh, Kevin Neil Aranha, U Sampritha, H Prema
The Egyptian Journal of Radiology and Nuclear Medicine
Venous Thromboembolism Diagnosis and Management
article

Optimizing CT pulmonary angiography: comparison of radiation dose, contrast volume, and image quality between standard and low-dose protocols

Mahadevappa Mahesh, Kevin Neil Aranha, U Sampritha, H Prema
article en

Abstract

Abstract Background Pulmonary embolism (PE) is a potentially life-threatening condition that requires prompt and accurate diagnosis. Computed tomography pulmonary angiography (CTPA) is the reference standard for PE detection; however, it carries risks of radiation exposure and contrast-induced nephropathy, particularly in younger patients and those requiring repeated scans. This study aimed to evaluate whether a combined low-dose, low-contrast CTPA protocol could achieve diagnostic image quality comparable to the standard protocol. Methods In this prospective comparative study, 44 patients with clinically suspected PE were enrolled. The control group ( n = 22) underwent standard CTPA (120 kVp, 90 mL contrast), while the experimental group ( n = 22) received an optimized protocol (100 kVp, 70 mL contrast, automatic tube current modulation, and 50% ASiR-V iterative reconstruction). Radiation dose parameters and contrast usage were recorded. Subjective image quality was graded by two blinded radiologists using a 5-point Likert scale, and quantitative metrics Hounsfield units (HU), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were compared between groups. Results The optimized protocol achieved a 39.6% reduction in effective dose (2.65 ± 0.54 mSv vs. 4.39 ± 0.62 mSv; p ≤ 0.001) and a 22.2% reduction in contrast volume (70 mL vs. 90 mL). Subjective image quality was comparable between groups ( p = 0.606). Quantitative analysis revealed no significant differences in SNR, CNR, or vascular attenuation ( p > 0.05). Interobserver agreement was excellent (ICC = 0.91). Conclusions A low-dose, low-contrast CTPA protocol can substantially reduce patient radiation and contrast exposure while maintaining diagnostic image quality. This approach supports the ALARA principle and may serve as a practical, cost-effective standard for routine PE imaging, especially in resource-limited or high-risk patient settings.

The Egyptian Journal of Radiology and Nuclear MedicineVol. 56(1)
Father Muller Medical College Hospital (IN)
Openalex Percentile: Top 46%
Venous Thromboembolism Diagnosis and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.