Remote Follow-Up Using Smartphone Apps, Telemedicine, and Wearable Activity Sensors After Joint Replacement: A Narrative Review

Digital health tools such as smartphone applications, telemedicine platforms, wearable activity sensors, and emerging smart implants are positively influencing postoperative follow-up after joint replacement. This narrative review synthesizes recent advances and evidence across these modalities. Smartphone apps consistently improve patient engagement, adherence, pain management, and functional recovery, while enabling scalable data capture. Wearables provide objective, continuous measures of mobility and range of motion and have shown acceptable accuracy in arthroplasty populations. Combined app-plus-sensor programs, including self-directed rehabilitation, achieve clinical outcomes comparable to standard care in randomized trials and can reduce costs and in-person visits. Telemedicine and home-based telerehabilitation demonstrate noninferiority to face-to-face physiotherapy for total joint arthroplasty, with high patient satisfaction and logistical advantages. Smart implants, though earlier in clinical adoption, yield unique biomechanical insights that may personalize rehabilitation and enable early detection of complications. Key challenges include heterogeneous study designs and metrics, device placement-dependent accuracy, digital literacy and connectivity barriers (especially among older adults or rural patients), data security and regulatory considerations, and technical constraints for implant power and wireless communication. Overall, remote follow-up using apps and wearables is a credible adjunct, or alternative, to conventional pathways after joint replacement; scaling impact will require standardized outcomes, interoperability, robust privacy safeguards, and prospective trials that link digital signals to meaningful clinical endpoints.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-11-12
DOI
https://doi.org/10.7759/cureus.96693
Citations
1
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
2.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Remote Follow-Up Using Smartphone Apps, Telemedicine, and Wearable Activity Sensors After Joint Replacement: A Narrative Review

Ahmed E Abdellatif, Abdelrahman Sayed, Mohammad Moniruzzaman Monir, Ali Soffar et al.
1 citations
Cureus
Total Knee Arthroplasty Outcomes
2.01
article

Remote Follow-Up Using Smartphone Apps, Telemedicine, and Wearable Activity Sensors After Joint Replacement: A Narrative Review

Ahmed E Abdellatif, Abdelrahman Sayed, Mohammad Moniruzzaman Monir, Ali Soffar, Ahmed Elkohail, Mohamed Elbanna, Kerementi Othieno-P'Otonya, Hassan A Kassem
article en
1 citations

Abstract

Digital health tools such as smartphone applications, telemedicine platforms, wearable activity sensors, and emerging smart implants are positively influencing postoperative follow-up after joint replacement. This narrative review synthesizes recent advances and evidence across these modalities. Smartphone apps consistently improve patient engagement, adherence, pain management, and functional recovery, while enabling scalable data capture. Wearables provide objective, continuous measures of mobility and range of motion and have shown acceptable accuracy in arthroplasty populations. Combined app-plus-sensor programs, including self-directed rehabilitation, achieve clinical outcomes comparable to standard care in randomized trials and can reduce costs and in-person visits. Telemedicine and home-based telerehabilitation demonstrate noninferiority to face-to-face physiotherapy for total joint arthroplasty, with high patient satisfaction and logistical advantages. Smart implants, though earlier in clinical adoption, yield unique biomechanical insights that may personalize rehabilitation and enable early detection of complications. Key challenges include heterogeneous study designs and metrics, device placement-dependent accuracy, digital literacy and connectivity barriers (especially among older adults or rural patients), data security and regulatory considerations, and technical constraints for implant power and wireless communication. Overall, remote follow-up using apps and wearables is a credible adjunct, or alternative, to conventional pathways after joint replacement; scaling impact will require standardized outcomes, interoperability, robust privacy safeguards, and prospective trials that link digital signals to meaningful clinical endpoints.

CureusVol. 17(11)
Andalusian Health Service (ES), King's College London (GB), Princess Royal University Hospital (GB), University Hospital of Wales (GB), Epsom and St Helier University Hospitals NHS Trust (GB), University Dental Hospital on Cardiff University (GB), King's College Hospital NHS Foundation Trust (GB), General Organization For Teaching Hospitals and Institutes (EG), Cardiff University (GB)
Openalex Percentile: Top 10%
Total Knee Arthroplasty Outcomes
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.